Crestron electronic WMKM-6X-DSW Manual Do Utilizador

Página de 16
 Mud Mount Kits for the TPS-6X-DSW 
Crestron MMK/WMKM-6X-DSW
 
Bend Flanges – 1 of 4 Flanges Bent 
BACK OF DRYWALL
 
10.  Use four standard drywall screws (length should not exceed drywall 
thickness by more than 1/2 inch) to secure the mud ring plate to the 
adjustment/mounting plate assembly. The screws are secured in the 
extruded holes of the adjustment plate and pass through the clearance 
holes in the mounting plate. 
11.  Verify that the plate is level before tightening. 
NOTE:  Do not over tighten screws. Doing so may damage the plate. 
12.  Use a #2 Phillips screwdriver and tighten the drywall screws by hand 
so that they slightly dimple into the holes in the mud ring plate. 
13.  Run the necessary cables for the TPS-6X-DSW and secure them behind 
the drywall. 
14.  Apply drywall joint compound as needed to finish the cutout. Avoid 
covering the four tapped mounting holes. 
15.  When the joint compound is dry, the wall mount docking station can be 
installed using the four tapped holes in the mounting plate. Refer to the 
latest revision of the TPS-6X-DSW Operations and Installation Guide 
(Doc. 6708) for details. Refer also to the comprehensive illustration on 
the following page. 
10  
  Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 
Installation Guide – DOC. 6779A