Chauvet intimidator 200 Manual Do Utilizador
Intimidator™ Scan LED 200 User Manual (Rev. 02a)
Page 7 of 22
3.
S
ETUP
AC Power
This product has an auto-ranging power supply and it can work with an input voltage
range of 100~240 VAC, 50/60 Hz.
range of 100~240 VAC, 50/60 Hz.
To determine the power requirements for a particular fixture, see the label affixed to
the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s
listed current rating indicates its average current draw under normal conditions.
the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s
listed current rating indicates its average current draw under normal conditions.
Always connect this product to a protected circuit (circuit breaker or fuse),
making sure that it has an appropriate electrical ground to avoid the risk of
electrocution or fire.
making sure that it has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
Disconnect this product from the power outlet before replacing the fuse.
1) Disconnect the fixture from the power outlet.
2) With a Phillips #2 head screwdriver, unscrew the fuse
holder cap from its housing.
3) Remove the blown fuse and replace it with a good
fuse of the same type and rating (F 3.15 A @ 250 V).
4) Screw the fuse holder cap back in its place and
reconnect power.
Always replace a blown fuse with a good fuse of the same type and rating.