Planning the Installation
Cabinet Layout
 wArning
To reduce the risk of personal injury caused by reaching 
over a hot appliance, cabinet storage space located 
directly above the range should be avoided.
MiniMuM cABinet width
Models
e
EH3012, EH3018, MH3012, MH3018
30” (76.2 cm)
EH3612, EH3618, MH3612, MH3618
36” (91.5 cm)
EH4212, EH4218
42” (106.7 cm)
EH4812, EH4818, MH4812, MH4818
48” (121.9 cm)
EH5418
54” (137.2 cm)
All tolerances: +1/16”, -0, unless otherwise stated
 wArning
Observe all governing codes and ordinances during planning and installation. Contact your local building department for 
further information.
 iMportAnt
See the diagram for minimum installed distance from 
the hood to the cooktop surface. The minimum specified 
distance may be higher for the particular range or 
cooktop in use. Check the manufacturers specifications 
for the cooktop or range.
Carefully check the location where the hood is to be 
installed. The hood should be placed for convenient 
access. Make certain that electric power can be provid-
ed in the selected location. The hood must be centered 
horizontally over the cooktop/range.
The hood model selected must be as wide as the 
cooktop surface or wider.
Plan the installation so that all minimum dimensions are 
met or exceeded. Dimensions shown provide minimum 
clearances, unless otherwise noted.
All contact surfaces between the hood and any cabi-
nets or walls must be solid and at right angles.
Install the range hood and cooking appliance(s) so that 
they can be removed if service is required.
Power Supply
 wArning
The electric service to the range hood should be installed 
only by a licensed electrician.
It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a qualified 
electrician. The electrical installation, including minimum 
supply wire size and grounding, must be in accordance 
with the National Electric code ANSI/NFPA* (or latest revi-
sion) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
The ground terminal on the hood must be connected 
to a grounded, metallic, permanent wiring system or 
grounding conductor installed by a licensed electrician.
Do not ground the appliance or appliance wiring to a 
gas pipeline or to the neutral (white) power supply wire.
Do not install a fuse in the neutral or ground circuit.
Connect the hood directly to an electrical junction box. 
Hard-wire the hood according to local code directly to 
a dedicated three wire grounded, single phase circuit 
rated at 120 Vac 60 Hz, 15 Amp.
E
25” Min.
(63.5 cm)
Electrical 
 Access