opTional gaS line inSTallaTion
Figure 21 - Gas Line Knockout
Side 
Firebrick 
Finished 
Side
Refractory 
Knockout 
Plug
Outside of 
Fireplace
Gas Line 
Conduit
Insulation
Gas 
Conduit 
Cover
1/2" Dowel
Gas  line  hook  up  should  be  done  by  your 
supplier or a qualified service person.
Note:  Before  you  proceed,  make  sure  your 
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1.  Remove knockout indentation on refracto-
ry or firebrick wall located above refractory 
hearth  floor.  Knockout  indentation  must 
be  firmly  tapped  with  any  solid  object, 
such as a 1/2" dowel, until it is released. 
Remove fragmented portions of refractory 
(see Figure 21).
2.  Remove gas line cover plate located on 
either side of fireplace and pull out insu-
lation from gas line conduit sleeve. Save 
insulation for reuse.
3.  Run a 1/2" black iron gas line into fire-
place  through  rear  at  gas  line  conduit 
sleeve  (if  using  a  raised  platform,  add 
height).  Provide  sufficient  gas  line  into 
fireplace chamber for fitting connection 
(see Figure 22).
 
Note: Secure incoming gas line to wood 
framing  to  provide  rigidity  for  threaded 
end.
4.  Repack insulation around gas line and into 
sleeve opening. Seal any gaps between 
gas line and refractory knockout hole with 
refractory cement or commercial furnace 
cement. Install gas appliance or cap off 
gas line if desired.
 CAUTION: All gas piping and 
connections must be tested for 
leaks  after  installation  is  com-
pleted. After ensuring that gas 
valve is on, apply soap and water 
solution to all connections and 
joints. Bubbles forming show a 
leak. Correct all leaks at once. 
DO NOT USE AN OPEN FLAME 
FOR  LEAK  TESTING  AND  DO 
NOT OPERATE ANY APPLIANCE 
IF A LEAK IS DETECTED. LEAK 
TESTING  SHOULD  BE  DONE 
BY  A  QUALIFIED  SERVICE 
PERSON.
Note: A FMI PRODUCTS, LLC hood must be 
installed when using an unvented gas log set 
(see Accessories on page 18).
 WARNING: Do not operate an 
unvented gas log set in this fire-
place with chimney removed.
If you install a decorative gas appliance (vent-
ed gas log), decorative gas appliance must 
comply with the Standard for Decorative Gas 
Appliance for Installation in Solid Fuel Burning 
Fireplaces, ANS Z21.60, Z21.84 or RG 2-72
 
and shall also be installed in accordance with 
the National Fuel Gas Code, ANSI 7223NFPA 
54 latest edition
.
 
WARNING: To avoid the risk 
of damaging fireplace materials 
and increasing the risk of spread-
ing a fire, do not use fireplace to 
cook or warm food.
Seal 
Opening 
with 
Refractory 
Cement
Outside of 
Fireplace
Gas 
Line 
Conduit
Repack 
Insulation
Incoming 
1/2" Black 
Iron Pipe
Side 
Firebrick 
Finished 
Side
Provide Enough Threaded 
End for Fitting Connection
Figure 22 - Gas Line Installation