Fisher d500243x012 Manual Do Utilizador

Página de 24
1035/El-O-Matic Actuator
Instruction Manual
Form 5417
February 2007
3
Table 2Performance Characteristics
E SERIES
ACTUATOR
BORE
STROKE
AVERAGE
STROKE
FREE AIR VOLUME
(2)
FREE AIR
VOLUME
(2)
ACTUATOR
SIZE
mm
Inch
mm
Inch
STROKE
TIME
(SEC)
(1)
Port
‘‘A’’(liter)
Port
‘‘A’’(in
3
)
Port
‘‘B’’(liter)
Port
‘‘B’’(in
3
)
E25
56
2.2
15.7
0.62
0.5
0.1
6.1
0.11
6.7
E40
70
2.8
18.8
0.74
0.7
0.16
9.8
0.22
13.4
E85
80
3.1
22.0
0.87
1.1
0.33
20.1
0.36
22.0
E100
91
3.6
25.1
0.99
1.2
0.35
21.4
0.49
29.9
E200
110
4.3
37.7
1.48
2.2
0.8
48.8
1.0
61.0
E350
145
5.7
37.7
1.48
3.7
1.8
110
1.9
116
E600
175
6.9
44.0
1.73
3.3
2.9
177
3.1
189
E950
200
7.9
50.3
1.98
5.4
4.7
287
4.9
299
E1600
230
9.1
62.8
2.47
5.8
7.3
445
8.0
488
P2500/P2505
300
11.8
56.5
2.22
6.7
8.0
488
9.3
567
P4000/P4005
325
12.8
81.7
3.22
12.4
13.5
824
17.5
1068
1. These times assume smaller solenoids for smaller actuators and larger solenoids for larger actuators with varying Cvs, but a constant air supply pressure of 80 psi (5.51 bar). E25 to
E350 assume a 0.09 Cv (0.08 Kv); E600 & E9500 a 0.26 Cv (0.22 Kv); E1600, P2505 & P4005 a 0.51 Cv (0.44 Kv).
2. To calculate air consumption per stroke multiply free air volume X air supply pressure (absolute).
Figure 2. Typical Actuator Assembly
SPRING
STANDARD SQUARE END
STANDARD SQUARE
DOUBLE D CONNECTION
COUPLER
DOUBLE ACTING
ACTUATOR
E SERIES INSERT
END CAP SPRING RETURN
W6954 / IL