3.2
CONFIGURING DIP-SWITCHES   
PI
SA
The GX/TM2 plug-in module has two board-mounted DIP-switches.  The standalone unit has one bank of
DIP-switches.  The locations of the DIP-switches are illustrated below.
Switch 1
Switch 4
Left
Switch 1
Switch 8
Bank 2
Bank 1
Right
SW1
SW8
Bank 1
Up
Down
DIP-switch Locations
3.2.1
Board-Mounted Bank 1 Settings   
PI
SA
DIP-switch Bank 1 is available on both the plug-in and standalone modules.  The table indicates the position
of the switch; Left/Down or Right/Up.  As indicated in the DIP-switch location diagram, Left and Right
refers to the plug-in module and Down and Up refers to the standalone module.
PI
 
(Left/Right)
SA
 
(Up/Down)
Switch
Left/Down
(Factory Default)
Right/Up
SW1
 AN:
Fiber Auto-Negotiation
 Man:
Fiber Manual Negotiation
SW2
 AN:
 UTP Auto-Negotiate
 Man:
 UTP Manual
SW3
 1000:
 UTP 1000Mbps
 10-100:
 UTP 10-100Mbps
SW4
 100:
 UTP 100Mbps
 10:
 UTP 10Mbps
SW5
 FDX:
 UTP Full-Duplex
 HDX:
 UTP Half-Duplex
SW6 - SW8 See Link Mode DIP-Switch Table in Section 3.2.1.6
3.2.1.1
SW1 - Fiber  Auto/Manual Negotiation “AN Man”
When this DIP-switch is in the Auto-Negotiate “AN” position (factory default), the fiber optic port
automatically determines the duplex and pause modes of the connecting fiber optic device.  If the connecting
fiber optic device cannot provide the proper signal to indicate its own mode of operation, the DIP-switch
should be set to the Manual mode “Man” position.
Page 6