For detailed information on the operation of the different Link Modes, download the application note
iConverter Link Modes” available on Omnitron’s web page:
http://www.omnitron-systems.com/downloads.php
3.2.2
Board-Mounted Bank 2 Settings    
PI
DIP-switch Bank 2 is available on the plug-in module only.
Switch
Left (Factory Default)
Right
SW1
 A-DS: Port A Disabled
 A-EN: Port A Enabled
SW2
 B-DS: Port B Disabled
 B-EN: Port B Enabled
SW3
 M/SL:
 Master/Slave Auto-Select
 SL:
 Slave-Mode Only
SW4
 Reserved
 Reserved
3.2.2.1
SW1 - Backplane Port A Enabled “A-DS/A-EN”
When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the GX/TM2 is
isolated from the chassis Backplane.  When the DIP-switch is in the Right “A-EN” position, Backplane
Port A of the GX/TM2 is enabled.  This port allows Ethernet Backplane connectivity to an adjacent module
via the chassis Backplane Port A.  See the backplane illustrations in Section 2.1.3.
3.2.2.2
SW2 - Backplane Port B Enabled “B-DS/B-EN”
When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the
chassis Backplane.  When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled.
This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B.
See the backplane illustrations in Section 2.1.3.
3.2.2.3
SW4 - Master/Slave Auto-Select and Slave-Only “M/SL / SL
When multiple management modules such as the 
iConverter
 Network Management Module (NMM) and
the GX/TM2 (or multiple self-managed modules such as the 10/100M) are installed in the same chassis,
only one management module can act as the chassis master.  The master management module has the
ability to make changes to the settings of the other modules in the chassis, while the slave management
modules cannot make the changes.  If an NMM is installed in the chassis, the NMM will always be the
master, otherwise the lowest slot number with a management module installed will become chassis master.
When this DIP-switch is in the Left “M/SL” position (factory default), the assignment of mastership is
automatically negotiated by the installed management modules.  To designate a specific management module
as the master when no NMM is installed in the chassis, set the DIP-switch on the master module to the Left
“M/SL” position, and set the other installed management modules’ DIP-switches to the Right “SL” position
to enable Slave-Only mode.
Only the chassis master can change configuration settings of other modules.
3.2.2.4
SW4 - Reserved
This DIP-switch is for factory use only.
NOTE:  DIP-switch marked Reserved must be kept in the Left (factory default) position.
Page 9