IMPORTANT: Vent-free gas log heaters add 
moisture to the air. Although this is beneficial, 
installing  firebox  in  rooms  without  enough 
ventilation air may cause mildew to form from 
too much moisture. See Air for Combustion 
and Ventilation
, page 7. 
IMPORTANT:  Make  sure  firebox  is  level. 
If  firebox  is  not  level,  log  set  will  not  work 
properly. 
Note: Your firebox is designed to be used in 
zero clearance installations. Wall or framing 
material can be placed against any exterior 
surface on the rear, sides, top or bottom of 
your firebox, except where standoff spacers 
are integrally attached. If standoff spacers are 
attached to your firebox, these spacers can 
be placed directly against wall or framing ma-
terials. Use the dimensions shown for rough 
opening to create the easiest installation.
Use  dimensions  shown  for  rough  openings 
to create the easiest installation (see Built-In 
Firebox Installation
, page 11).
INstAllAtIoN cleARANces
  WARNING:  maintain  the 
minimum clearances. if you can, 
provide greater clearances from 
floor, ceiling and adjoining wall.
Carefully  follow  these  instructions. This  will 
ensure safe installation.
Minimum wall and Ceiling Clearances (see 
figure 5)
A.  Clearances  from  the  side  of  fireplace 
cabinet to any combustible material and 
wall should follow diagram in Figure 5.
 
Example: The face of a mantel, bookshelf, 
etc. is made of combustible material and 
protrudes 3 
1
/
2
" from the wall. This com-
bustible material must be 4" from the side 
of the fireplace cabinet (see Figure 5).
B.  Clearances from the top of firebox opening 
to ceiling should not be less than 42".
C.  When firebox is installed on carpeting or 
other  combustible  material,  other  than 
wood flooring, firebox should be installed 
on a metal or wood panel extending the 
full width and depth of enclosure.
D.  Clearances from bottom of firebox to the 
floor is 0".
These fireboxes can be installed as freestand-
ing  units  against  a  wall  with  the  approved, 
INSTALLATION
Continued
*Minimum 16" from Side Wall 
*
optional  cabinet  mantels  (see  Accessories
page 18) or as a built-in unit. Clearances are the 
same for either installation method. 
  cAutIoN:  do  not  install 
the  firebox  directly  on  carpet 
or vinyl. 
Example
mantel clearances for built-In Installation
If placing custom mantel above built-in firebox, 
you must meet the minimum allowable clear-
ance between mantel shelf and top of firebox 
opening shown in Figure 6, page 11. These 
are the minimum allowable mantel clearances 
for a safe installation. Use larger clearances 
wherever possible to minimize the heating of 
objects and materials placed on the mantel.
 cAutIoN: do not allow the 
vent-free gas log heater to touch 
or extend beyond the fireplace 
screen.
notiCe: surface temperatures 
of  adjacent  walls  and  mantels 
become  hot  during  operation. 
walls  and  mantels  above  the 
firebox  may  become  hot  to 
the touch. if installed properly, 
these  temperatures  meet  the 
requirement  of  the  national 
product  standard.  follow  all 
minimum clearances shown in 
this manual.