fisher--paykel mw612 Manual Do Utilizador

Página de 40
5
Installation Instructions
Inlet Hoses
Connect the straight ends of the inlet hoses to the taps. There are 
washers fitted in both ends.
2
  Connect the elbow ends of the inlet hoses to the machine inlet 
valves.  Inlet valves are marked on the back of the machine
   
 
H=Hot    
C=Cold.
Cold supply only:
If you only have a cold water supply, an inlet valve cap (blanking cap) MUST be connected to the 
hot inlet valve. The cap prevents water leaking out of the hot valve. The cap is available from your 
Fisher & Paykel Dealer or Authorised Service Centre, Part No. 388491. This appliance incorporates 
backflow protection complying with AS3500.1. No further backflow protection is required for 
connection to the water supply.
Levelling
It is IMPORTANT to level the machine to ensure even spin 
performance.
1
  Separate the 4 rubber foot inserts from the moulding and 
fit into the feet on the base of the machine.
2
  Move the machine to its final position. (We suggest a 
minimum clearance of 20mm each side).
3
  Adjust the feet so the machine is level and cannot rock.
To check if your machine is level:
Look down on the wash bowl and make sure it sits slightly forward of centre (see Diagram 1).
  Close the lid. Visually check that the lid fits evenly on both sides. If it does not look like the 
diagram in the middle, adjust one of the front feet slightly until it matches. The diagram on the 
top and bottom are not correct (see Diagram 2).
4
  Turn on the water and check all hose connections for leaks. Make sure there are no kinks in the hoses.
5
  Uncoil power cord and plug into wall socket.
Adjustable feet
Rubber insert
Tap end 
To check levelling look 
down on the wash bowl
Correct 
Incorrect 
Diagram 1
Lid Alignment
Lid
Topdeck
Wind right foot down 
(out) to correct
Wind left foot down 
(out) to correct
Lid
Lid
Topdeck
Topdeck
Diagram 2
Machine end