TROUBLESHOOTING
 WARNING: Turn off and unplug heater and let cool before servicing. 
Only a qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor electrode positioned 
wrong
2. Ignitor electrode broken
3.  Ignitor  electrode  not  con-
nected to ignitor cable
4.  Ignitor  cable  pinched  or 
wet
5. Broken ignitor cable
6. Bad ignitor
7. Piezo ignitor nut (if equipped) 
is loose
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob is not in pilot 
position
3. Control  knob  not  fully 
pressed  in  while  pressing 
ignitor button
4. Air  in  gas  lines  when  in-
stalled
5. Depleted gas supply (pro-
pane/LP gas)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
1.  Not  enough  combustion/
ventilation air
OBSERvED PROBLEM
When  ignitor  button  is  
pressed in, there is no spark 
at ODS/pilot
When ignitor button is pressed 
in, there is a spark at ODS/Pilot 
but no ignition
Moisture/condensation  no-
ticed on windows
REMEDY 
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
5. Replace ignitor cable
6. Replace ignitor
7.  Tighten  nut  holding  piezo 
ignitor. Nut is located inside 
heater cabinet at top
1. Turn on gas supply or open 
equipment shutoff valve
2.  Turn  control  knob  to  pilot 
position
3.  Turn  to  PILOT/IGN  posi-
tion.  Fully  press  in  control 
knob  while  pressing  ignitor 
button
4.  Continue  holding  down 
control  knob.  Repeat  ignit-
ing  operation  until  air  is 
removed
5.  Contact  local  propane/LP 
gas company
6. Clean ODS/pilot (see Clean-
ing and Maintenance, page 
16)  or  replace  ODS/pilot 
assembly
7. Replace gas regulator
1. Refer to Air for Combustion 
and Ventilation requirements 
(page 5)