Campbell Hausfeld PL1551 Manual Do Utilizador

Página de 12
3
TL0504, TL0518, TL1005, TL1118, PL1551, FHT504, IFT218, PL1504, TL1004
www.chpower.com
Operation (Continued) 
maintenance
STOraGe
The air tool must be lubricated before 
storing. Follow the air motor lubrication 
instructions with an exception to step 4. Run 
the sander for only 2 to 3 seconds so more oil 
will remain in the air tool when storing.
TeCHnICaL ServICe
For information regarding the operation or 
repair of this product, please call 1-800-543-
6400.
 
Never carry a  
  tool by the hose 
or pull the hose to move the tool or 
a compressor. Keep hoses away from 
heat, oil and sharp edges. Replace any 
hose that is damaged, weak or worn.
Using fittings or air hoses which are too small 
can create a pressure drop and reduce the 
power of the tool. A 3/8” (I.D.) fitting with 
1/4” NPT threads is recommended. Most 
compressors are shipped with a short, 1/4” 
I.D. hose. For proper performance and more 
convenience, use a 3/8” I.D. hose. Hoses 
longer than 50 feet should have a 1/2” I.D.
Troubleshooting Chart
Symptom
Possible Cause(s)
Corrective action
   Tool runs slowly or will not operate.
1.    Grit or gum in tool
1.    Flush the tool with Campbell Hausfeld air tool oil, gum 
solvent, or an equal mixture of SAE 10 motor oil and 
kerosene. If Campbell Hausfeld oil is not used, lubricate 
the tool after cleaning
2.  No oil in tool
2.    Lubricate the tool according to the lubrication 
instructions in this manual
3.    Low air pressure
3a. Adjust the regulator on the tool to the maximum setting 
(If applicable)
3b. Adjust the compressor regulator to tool maximum while 
the tool is running free
4.    Air hose leaks
4.    Tighten and seal hose fittings if leaks are found
5.    Pressure drops
5a. Be sure the hose is the proper size. Long hoses or tools 
using large volumes of air may require a hose with an 
I.D. of 1/2” or larger depending on the total length of 
the hose
5b. Do not use multiple number of hoses connected together 
with quick connect fittings. This causes additional 
pressure drops and reduces the tool power. Directly 
connect the hoses together
6.    Regulator set too low
6.    Adjust regulator until tool reaches maximum speed
Moisture blowing out of tool
1.    Water in tank
1.    Drain tank. (See air compressor manual). Oil tool and 
run until no water is evident. Oil tool again and run 1-2 
seconds
2.    Water in the air lines/hoses
2a. Install a water separator/filter (PA2121). NOTE: Separators 
only work properly when the air passing through the 
separator is cool. Locate the separator/filter as far as 
possible from the compressor
2b. Install an air dryer
2c. Anytime water enters the tool, the tool should be oiled 
immediately
 Sander stops when applied to work surface
  Spindle lock is in the locked 
position
Unlock spindle (See Figure 1)