Carrier GT-S Manual Do Utilizador

Página de 56
Carrier
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
46
Equipment Selection 
The installation of geothermal heat pump units and all 
associated components, parts, and accessories which 
make up the installation shall be in accordance with 
the regulations of ALL authorities having jurisdiction 
and MUST conform to all applicable codes. It is the 
responsibility of the installing contractor to determine 
and comply with ALL applicable codes and regulations.
General
Proper indoor coil selection is critical to system 
effi ciency.  Using an older-model coil can affect 
effi ciency and may not provide the customer with 
rated or advertised EER and COP. Coil design and 
technology have dramatically improved operating 
effi ciency and capacity in the past 20 years. 
Homeowners using an older coil are not reaping 
these cost savings and comfort benefi ts. NEVER 
MATCH AN R-22 INDOOR COIL WITH AN R-410A 
COMPRESSOR SECTION.
Newer indoor coils have a larger surface area, 
enhanced fi n design, and grooved tubing. These 
features provide a larger area for heat transfer, 
improving effi ciency and expanding capacity. Typical 
older coils may only have one-third to one-half the face 
area of these redesigned coils.
Indoor Coil Selection - GT-PX (50YDS) Puron® 
Geothermal Split System
Geothermal split system heat pumps are rated in the 
ARI directory with a specifi c indoor coil match.  GT-
PX Puron split system (50YDS) models are rated with 
Carrier/Bryant FV4 or FE4 series variable speed air 
handlers as shown in Table 1a.  Other combinations 
(e.g. variable speed furnace with cased coil) may attain 
the same ARI ratings providing that the specifi cations 
meet or exceed those listed in Table 1a AND Table 
1b.  An ECM motor and TXV is required.  Cap tubes 
and fi xed orifi ces are not acceptable.  PSC fans may 
be used if matched to Table 1b, but will not meet ARI 
ratings. If using PSC fan, compressor section must be 
operated as a single stage unit (i.e. wired for either 
1st stage or 2nd stage). Without the ability to vary the 
airfl ow, supply air temperatures may not be acceptable if 
the compressor is allowed to change stages when used 
with a PSC fan motor.
Table 1a: GT-PX (50YDS) Puron® Geothermal Split System Air Handler Matches for ARI Ratings
Compressor Section
026
038
049
064
Air Handler
Model FV4 or FE4
003
005
006
006
Refrigerant
R-410A
Metering Device
TXV (required)
Air Coil
     Type
     Rows - Fins/in.
     Face Area (sq. ft.)
Slope
3 - 14.5
3.46
A
3 - 14.5
5.93
A
3 - 14.5
7.42
A
3 - 14.5
7.42
Cabinet Confi guration
Upfl ow / Downfl ow / Horizontal (Multipoise)
ECM Settings for 
ARI Ratings
(FV4 Fan Coil)
AC/HP size:  036
System Type:  
Comfort AC/HP
CFM Adjust: Nom
AC/HP size:  036
System Type:  
HP-Effi c AC/HP
CFM Adjust: High
AC/HP size:  048
System Type:  
Comfort AC/HP
CFM Adjust: High
AC/HP size:  060
System Type:  
Comfort AC/HP
CFM Adjust: High
Fan Motor Type - HP
ECM - 1/2
ECM - 1/2
ECM - 3/4
ECM - 3/4
GT-PX Air Handler Matches for ARI Ratings