Chauvet 350 Manual Do Utilizador

Página de 19
 
 
 
 
Intimidator™ Spot LED 350 User Manual (Rev. 4) 
Page 7 of 19 
3.
 
S
ETUP
 
AC Power 
The Intimidator™ Spot LED 350 has an auto-ranging power supply and it can work with 
an input voltage range of 100~240 VAC, 50/60 Hz. 
To determine the  product’s  power requirements (circuit breaker, power outlet, and 
wiring),  use the current value listed on  the label affixed to the product’s back panel, or 
refer to the product’s specifications chart. The  listed current rating indicates the 
product’s average current draw under normal conditions. 
 
 
 
Always connect the product to a protected circuit (circuit breaker or fuse). Make 
sure the product has  an appropriate electrical ground to avoid the risk of 
electrocution or fire. 
 
 
 
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even 
if the rheostat or dimmer channel serves only as a 0 to 100% switch. 
 
 
Fuse 
Replacement
 
Follow the instructions below to change the fuse, if necessary.
 
 
 
 
Disconnect the product from the power outlet before replacing the fuse. 
 
 
 
1.  Disconnect this product from the power outlet.  
2.  Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing. 
3.  Remove the blown fuse and replace with a good fuse of the same type and rating. 
4.  Screw the fuse holder cap back in place and reconnect power. 
 
 
 
 
 
The product does not ship with a spare fuse; however, the safety cap has room 
for a spare.