Desa cspbnt Manual Do Utilizador

Página de 24
www.desatech.com
111487-01E
4
4.  This heater shall not be installed in a bedroom 
or bathroom.
5.  Do  not  place  stove  directly  on  carpeting, 
vinyl tile or any combustible material other 
than wood. The stove must set on a metal 
or wood panel extending the full width and 
depth of the appliance.
6.  Do not use this stove as a wood burning fire-
place. Use only model 111485-02/111485-01 
vent-free gas log heater.
7.  Do not add extra logs or ornaments such as pine 
cones, vermiculite or rock wool. Using these 
added items can cause sooting.
8.  This log heater is designed to be smokeless. If 
logs ever appear to smoke, turn off heater and 
call a qualified service person. Note: During 
initial operation, slight smoking could occur 
due to log curing and heater burning manu-
facturing residues. 
9.  To prevent the creation of soot, follow the 
instructions in Cleaning and Maintenance, 
page 14.
10.  Before  using  furniture  polish,  wax,  carpet 
cleaners or similar products, turn heater off. 
If heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture. 
11.  This heater needs fresh, outside air ventilation to 
run properly. This heater has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS shuts down the heater if not enough fresh 
air is available. See Air for Combustion and 
Ventilation, page 5. If heater keeps shutting 
off, see Troubleshooting, page 16.
12.  Do not run heater
• where flammable liquids or vapors are used 
or stored
• when under dusty conditions
13.  Do not use this stove to cook food or burn paper 
or other objects.
14.  Do not use heater if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the room heater 
and to replace any part of the control system and 
any gas control which has been under water. 
15.  Do not operate heater if any log is broken. Do 
not operate heater if a log is chipped (dime-
sized or larger). 
16.  Turn heater off and let cool before servicing. 
Only a qualified service person should service 
and repair heater.
SAFETY INFORMATION
Continued
17.  Operating heater above elevations of 4,500 
feet could cause pilot outage. 
18.  For propane/LP units, do not use propane/LP 
tank of less than 100 lb. capacity.
19.  Provide  adequate  clearances  around  air 
openings. 
20.  Screen must be completely closed before using 
heater. Never run heater with screen open.
PRODUCT 
IDENTIFICATION
Figure 1 - Typical Stove Cabinet Model 
with Comfort Glow Gas Log Heater
Stove 
Body
Stove Door 
(Shown in the 
open position)
Piezo 
Ignitor
Control 
Knob
One Piece Log Set 
Inside Stove Cavity
Screen
LOCAL CODES
Install and use heater with care. Follow all local 
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI 
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269