Lowrance electronic lra-1800 Manual Do Utilizador

Página de 48
Section 2: Radar Setup 
Before you begin radar setup, the radar scanning unit, RIM 300 mod-
ule, radar processor and display unit all must be installed. 
WARNING: 
Do NOT attempt to execute Radar Setup, while the ves-
sel is moving. Some motion from wind and wave action is 
acceptable, but these setup instructions are NOT in-
tended for vessels moving across the water. 
Caution
If you are unsure or do not understand the following instruc-
tions, it is strongly recommended that an experienced radar 
technician handle radar setup and the installation of radar 
hardware. 
Getting Started 
1. Press 
MENU
|
MENU
, then use 
↑ ↓  to 
S
YSTEM 
S
ETUP
 and press 
ENT
2. Highlight 
C
OMMUNICATIONS 
P
ORT
 and press 
ENT
3. Press 
↓ to 
R
ADAR
 and press 
ENT
, which will place an X in the radar 
checkbox. The Baud Rate automatically will switch to 230400 and a 
Radar Notice will appear. 
 
 
Communications Port menu (left). Radar Notice (right) prompting us-
ers to leave radar in Standby Mode for 30 minutes when activating ra-
dar for the first time. 
Caution:  
Leave the radar in Standby Mode for 30 minutes when activat-
ing it the first time. This will help maximize the life of the mag-
netron. After the radar has been activated the first time, ignore 
the Radar Notice.