KVH Industries TracVision G4 Manual Do Utilizador

Página de 155
5.6
Replacing the Antenna Gyro
Assembly
1. Remove the main PCB cover, as described in
“Removing the Main PCB Cover” on page 106.
2. Using a 
3
8
" nut driver/socket, remove the four nuts
and washers securing the antenna gyro to the
reflector bracket (see Figure 5-8). The nut on the
bottom right also secures a cable clamp. Set the
nuts, washers, and cable clamp aside.
3. Disconnect the antenna gyro Molex connector
from the main PCB (see Figure 5-3 on page 107).
Remove the old antenna gyro assembly.
4. Connect the new antenna gyro’s Molex connector
to the main PCB.
5. Replace the antenna gyro gasket (see Figure 5-8).
Maintenance
54-0147
111
Make sure the cable passes
through the PCB access slot to
protect the wires from the edge of
the PCB frame.
Gyro
Gasket
Bracket
Figure 5-8
Replacing the Antenna Gyro
Assembly