When a symbol is defined, a pin is placed at a certain position.
PIN 'GND' PWR NONE SHORT R180 (0.2 0.4) ;
You draw a rectangular forbidden area in layer 41 tRestrict:
LAYER TRESTRICT;
RECT (0.5 0.5) (2.5 4) ;
5.3 Grids and the Current Unit
EAGLE performs its internal calculations using a basic grid size of
1/10 000 mm (0.1 micron). Any multiple of that can be set as the work-
ing grid.
Microns, mils, inches and mm can be used for the unit. The current unit
as set with the GRID command applies to all values.
You should always use the pre-set 0.1 inch grid for schematic diagrams.
This grid should also be used when defining schematic diagram symbols
in the Library Editor.
When starting the design of circuit boards or libraries it pays to give
prior thought to the question of which grid size (or sizes) will be used
as a basis. For example, it is only the origin of a package that will be
pulled onto the board’s placement grid. All other objects constituting
the package (such as pads) are placed relative to that point on the board,
just as it was defined in the library.
The basic rule for boards is: always make the grid as big as possible and
as small as necessary.
Various grid sizes can be preset in the eagle.scr file for different types of
editor windows (see page 79).
The Grid Menu
71
Principles for Working with EAGLE