ge-interlogix simon 3 Manual Do Utilizador
Simon Security System
48
Manual Lamp Module Control
•
Control Panel: Press the Lights On button and the unit # of the lamp module
using the numeric buttons to test individual lamp modules 2, 4, 6, and 8. The
panel responds with Lights # on/off. Press the Lights On button twice to turn on all
lamp modules. Press the Lights Off button twice to turn off all lamp modules.
using the numeric buttons to test individual lamp modules 2, 4, 6, and 8. The
panel responds with Lights # on/off. Press the Lights On button twice to turn on all
lamp modules. Press the Lights Off button twice to turn off all lamp modules.
•
Keychain Touchpad: Press the LIGHT button repeatedly to turn all lights on
and off. The panel responds with Lights on/off.
and off. The panel responds with Lights on/off.
•
Remote Handheld Touchpad: Press the Lights On button and the unit # of the
lamp module using the numeric buttons to test individual lamp modules 2, 4, 6,
and 8. The panel responds with Lights # on/off.
lamp module using the numeric buttons to test individual lamp modules 2, 4, 6,
and 8. The panel responds with Lights # on/off.
X10 Siren and Lamp Module Functions
All sirens turn off when the system is disarmed or when the siren timeout expires.
Siren priority is as follows:
Siren priority is as follows:
1.
Fire (highest priority)
2.
Intrusion
3.
Emergency
Note
The X10 Siren must be set
to unit #9 to “hear” emer-
gency alarms and Status
Beeps. To “hear” emer-
gency alarms only, set to
unit #10.
The X10 Siren must be set
to unit #9 to “hear” emer-
gency alarms and Status
Beeps. To “hear” emer-
gency alarms only, set to
unit #10.
If an alarm of greater priority occurs during an alarm of lower priority, the greater pri-
ority alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5
seconds off for three beeps then 1.5 seconds off).
ority alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5
seconds off for three beeps then 1.5 seconds off).
Emergency
Planning
Planning
Emergency Planning Floor Plan
Use the following guidelines when drawing an emergency floor plan for the home-
owner:
owner:
•
Show all building levels.
•
Show exits from each room (2 exits per room are recommended).
•
Show the locations of all security system components.
•
Show the locations of any fire extinguishers.
Alarm Siren and X10 Light Information
Fire
Intrusion
Emergency
X10 Lights
Steady
Flashing
Steady
X10 Siren
Steady
Steady
Alarm beeps
Interior & Panel Siren
Temporal 3
Steady
Fast on/off
Exterior Siren
Temporal 3
Steady