Furuno 1834C-BB Manual Do Utilizador

Página de 233
 
 
SP - 3 
 
3 TRANSCEIVER 
MODULE 
3.1  Frequency and Modulation  9410 MHz ±30MHz (X band), P0N 
3.2  Peak Output Power 
M1824C-BB: 2.2 kW nominal 
 
M1834C-BB /1934C-BB: 4 kW nominal 
 
M1944C-BB: 6 kW nominal 
   
M1954C-BB: 12 kW nominal 
   
M1964C-BB: 25 kW nominal 
3.3  Modulator 
FET Switching Method 
3.4  Intermediate Frequency  60 MHz 
3.5  Tuning 
Automatic or manual 
3.6  Receiver Front End 
MIC (Microwave IC) 
3.7  Bandwidth 
Tx pulselength 0.08 µs and 0.3 µs: 25 MHz 
 
Tx pulselength 0.8 µs: 3 MHz 
3.8  Duplexer 
Circulator with diode limiter 
3.9  Warming up 
90 s approx. 
 
4 INTERFACE 
4.1  Input Data 
IEC 61162-1 (NMEA 0183 Ver1.5/2.0) 
Own ship’s position: 
GGA>RMC>RMA>GLL 
Ship’s speed: 
RMC>RMA>VTG>VHW 
Bearing (True): 
HDT>HDG
*1
>HDM
*1
>VHW 
Bearing (Magnetic): 
HDM>HDG
*1
>HDT
*1
>VHW 
Course: RMC>RMA>VTG 
Water depth: 
DPT>DBT>DBS>DBK 
Wind: MWV>VWT>VWR 
Water Temperature: 
MTW 
Time: ZDA 
 
*1
: calculated by magnetic deviation 
4.2 Output Data 
  Alarm signal 
12 VDC, 100 mA or less 
NMEA 0183 Ver1.5 
GGA, GLL, RMA, RMC, GTD, VTG, ZDA (GPS data required) 
 
RMB, WPL, BWC or BWR, APB, AAM, BOD, XTE, VHW,   
                         MTW, DPT or DBT, DBS (ETR required), 
 
TLL (L/L, Heading data required), TTM (ARPA required)