OPERATION CONDITION
Use this air conditioner under the following temperature range
Single Split Outdoor Unit (CU-E7MKE, CU-E9MKE, CU-E12MKE, CU-E15MKE, CU-E18MKE, CU-E21MKE)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Max.
32
23
43
26
Min.
16
11
5
4
HEATING
Max.
30
-
24
18
Min.
16
-
-5
-6
NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -5°C.
When the outdoor temperature is below -5°C and you use this model out of above conditions, the outdoor unit might be 
frozen up and stop operation for protection control.
Multi Split Outdoor Unit (CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)
Temperature (°C)
Indoor
Outdoor
Outdoor
CU-2E15LBE, CU-2E18LBE, 
CU-4E27CBPG
CU-3E18LBE, CU-4E23LBE
*DBT
*WBT
*DBT
*WBT
*DBT
*WBT
COOLING
Max.
32
23
43
26
46
26
Min.
16
11
16
11
-10
-
HEATING
Max.
30
-
24
18
24
18
Min.
16
-
-10
-11
-15
-16
* DBT:  Dry bulb temperature
* WBT:  Wet bulb temperature
Single Split Outdoor Unit (CU-E7MKE-3, CU-E9MKE-3, CU-E12MKE-3)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Max.
32
23
43
26
Min.
16
11
5
4
HEATING
Max.
30
-
24
18
Min.
16
-
-15
-16
NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -15°C.
When the outdoor temperature is below -15°C and you use this model out of above conditions, the outdoor unit might be 
frozen up and stop operation for protection control at -18°C.