OCC DX012DALT9QR Fiber Optic Cable Guia De Especificação
Optical Cable Corporation reserves the right to change this specification without prior notification.
Distribution series Fiber optic cable
type oFnr riser proDuct speciFications
type oFnr riser proDuct speciFications
i/o 1
| inDoor/outDoor cables
Applications
• Indoor/outdoor tight-bound tight-buffered design allows cables to be installed
in intra-building backbone and inter-building campus locations without costly
transitions between cable types
• Ideal configuration for a single termination point requiring multiple fibers
in intra-building backbone and inter-building campus locations without costly
transitions between cable types
• Ideal configuration for a single termination point requiring multiple fibers
Features
• High performance components
and construction
• Cable materials are indoor/outdoor –
UL-listed OFNR and UV,
water and fungus resistant
• UL Listed in accordance
with NEC section 770.179(b)
and construction
• Cable materials are indoor/outdoor –
UL-listed OFNR and UV,
water and fungus resistant
• UL Listed in accordance
with NEC section 770.179(b)
for use in vertical runs in building
riser shafts or from floor to floor
• Wide operating temperature range
of -40°C to +85°C
• Helically stranded core for greater flexibility
• Wide operating temperature range
of -40°C to +85°C
• Helically stranded core for greater flexibility
and mechanical protection of the optical fibers
• High strength-to-weight ratio
• 2-144 fiber configuration is smaller and lighter
than comparable sub-grouped cables, which is
ideal for installation in areas with limited
space or tight bends
• Can be armored for additional protection in direct burial and aerial installations
• Interlocking armor can be applied to cables as an alternative to conduit installation
• High strength-to-weight ratio
• 2-144 fiber configuration is smaller and lighter
than comparable sub-grouped cables, which is
ideal for installation in areas with limited
space or tight bends
• Can be armored for additional protection in direct burial and aerial installations
• Interlocking armor can be applied to cables as an alternative to conduit installation
Cost savings
• 900 µm buffer eliminates the need for costly and time-consuming installation of
fanout kits or pigtail splices because connectors terminate directly to the fiber.
fanout kits or pigtail splices because connectors terminate directly to the fiber.
See page PI-4 for typical termination approach.
• No need to splice outdoor cable to indoor cable at building entrance
• High crush resistance may eliminate the need for innerduct
• No need to splice outdoor cable to indoor cable at building entrance
• High crush resistance may eliminate the need for innerduct
D-Series Riser
Mechanical and Environmental Performance
indoor/outdoor
Operating Temperature
-40°C to +85°C
Storage Temperature
-55°C to +85°C
Installation Temperature (cable temp.)
-10°C to +60°C
Flame Retardancy
UL Listed Type OFNR (UL 1666)
and FT4 (CSA C22.2 No. 232)
Impact Resistance:
1,500 impacts
Crush Resistance:
1,800 N/cm
Flex Resistance:
2,000 Cycles