Puls UZK12.071 Battery Guia De Especificação
UZK12.071, UZO12.07
U-Series
B
ATTERY
M
ODULE
12V,
7AH
10. R
EPLACING
B
ATTERIES
Disconnect battery fuse before replacing the battery.
Always dispose the battery through a recycling organization. Batteries must be completely discharged before
recycling. Batteries can also be returned to PULS or the battery manufacturer.
recycling. Batteries can also be returned to PULS or the battery manufacturer.
Battery replacements can be acquired through PULS. PULS also offers a list with recommended batteries in case
batteries need to be acquired elsewhere.
batteries need to be acquired elsewhere.
Fig. 10-1 Replacing the battery
To replace battery:
1) Loosen screw with only one turn and
2) Slide the mounting bracket sideways.
3) Tilt the mounting bracket to the front and
take it off
4) Unplug the battery terminals
5) remove the battery
6) To insert the new battery use same
procedure vice versa.
11. E
NVIRONMENT
Operational temperature
*)
-10°C
**)
to +40°C (14°F to 104°F)
for charging
-15°C to +50°C (5°F to 122°F)
for discharging
Storage temperature
-20°C to +50°C (-4°F to 122°F)
for storage and transportation
Humidity
5 to 95% r.h.
IEC 60068-2-30
Do not energize while condensation is present
Do not energize while condensation is present
Vibration sinusoidal
±4mm at 16.7Hz
fixed frequency for 1hour
fixed frequency for 1hour
Vibration in vertical mounting orientation
according to IEC/EN 61056-1
according to IEC/EN 61056-1
Shock
free fall from 20cm
onto a wooden floor
onto a wooden floor
Shock with bottom down orientation
according to IEC/EN 61056-1
according to IEC/EN 61056-1
Altitude
0 to 6000m (0 to 20 000ft)
without any restrictions
Degree of pollution
2
IEC 62103, EN 50178, not conductive
LABS compatibility
The unit does not release any silicone or other LABS-critical substances and is suitable for
use in paint shops.
use in paint shops.
*)
Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit.
**) Frequently charging below +5°C (41°F) reduced the lifetime of the battery
Jul. 2014 / Rev. 2.0 DS-UZK12.071
All parameters are specified at, 25°C ambient temperature unless otherwise noted.
All parameters are specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
4/9