Molex DRL-332M-SSC Ethernet Switch Guia De Especificação

Página de 3
Brad
®
Direct-Link
®
Industrial Ethernet
Switches
112036 Series 200 Unmanaged Switches
Series 300 Managed Switches
SPECIFICATIONS
Unmanaged Plastic Case
(DRL-2xxP) 
Unmanaged Metal Case
(DRL-2xxM)
Managed 
5 to 8 port
Managed 16/18 port
Ethernet protocols supported 
IEEE 802.3 protocols 
RJ45 ports 
10/100 Mbps auto-detecting, full or half duplex, 
auto-mdi/mdix-crossover, auto-polarity 
Ports 1-16 are 10/100 Base TX
Ports 17-18 are 10/100/1000 Base TX
Fiber optic ports 
100 Mbps, full duplex, SC or ST connector 
1000 Mbps LC 
Fiber optic multimode 
4 km typical, 1310 nm, for 50-62.5/125 um fiber 
0.55 km, 850 nm, 50-62.5/125 um
Fiber optic singlemode
20 km typical, 1310 nm, for 9-10/125 um fiber
10 km, 1310 nm, 9-10/125 um
Typical Latency 
5 us for 100 Mbps (plus frame time)
16 us for 10 Mbps (plus frame time) 
Ethernet Isolation 
1500 Vrms 1 minute 
MAC addresses supported 
1024
2048
8192
Memory bandwidth 
3.2 Gbps 
32 Gbps
Input voltage 
10 – 30V DC, dual redundant power inputs, reverse polarity protection 
Power consumption (all ports active) 
2.0 to 5.0W
3.6 to 6.3W
8.0 to 10.0W
Industrial surge and 
spike protection 
Transient: 15,000W peak
Spike: 5,000W (10 times for 10 us)
Alarm output
Same voltage as power input
0.5A max.
Unmanaged Plastic Case
(DRL-2xxP) 
Unmanaged Metal Case
(DRL-2xxM) 
Managed 5-8
port
Managed 16/18 port
Operating temperature 
-10 to +60°C
-40 to +85°C
-40 to +75°C
Storage temperature
-40 to +85°C
Enclosure rating
IP30
IP40 
IP30 
IP40 
Enclosure dimensions
5 port: 2.54cm (1.00") wide
10.03cm (3.95") high
8.28cm (3.26") deep
8 port: 3.81cm (1.50") wide
10.03cm (3.95") high
8.28cm (3.26") deep
5 port:  2.71cm (1.07") wide
13.21cm (5.20") high
10.69cm (4.21") deep
8 port:  4.07cm (1.60") wide
13.21cm (5.20") high
10.69cm (4.21") deep
16 port: 5.40cm (2.13") wide
15.29cm (6.02") high
11.80cm (4.65") deep
18 port: 7.31cm (2.88") wide
15.29cm (6.02") high
11.80cm (4.65") deep
Humidity
5 to 95% RH (non-condensing)
Vibration and shock
IEC60068-2-6, -27 and -32
Electrical safety 
UL508, CSA C22.2/14, EN61010-1, CE 
EMC 
FCC part 15, ICES-003, EN610006-2/4, CE 
Hazardous locations 
UL 1604, CSA C22.2/213 (Class I, Div 2, Groups) EN60079-15 (Zone 2, Category 3), CE (ATEX) 
RoHS 
Yes