Puls CS5.241 Power Supply Guia De Especificação

Página de 20
 
 
 
CS5.241, CS5.241-C1, CS5.241-S1 
 
  CSeries 
24V, 5A, S
INGLE 
P
HASE 
I
NPUT
 
 
 
Dec. 2006 / Rev. 1.3  DS-CS5.241-EN 
All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
3/20 
 
5. AC-I
NPUT
 
 
 AC 
input 
nom. 
AC 100-120V / 
200-240V 
auto-select input, TN-, TT-, IT-Mains, see 
Fig. 5-1
 
  AC input range 
 
90-132Vac 
100-120V range, continuous operation 
   
 
180-264Vac 
200-240V range, continuous operation 
   
 
85-90Vac 
Short term or with output derating 
   
 
264-300Vac < 
0.5s 
 Input 
frequency 
nom. 
50 – 60Hz  
±6% 
 
 
AC 100V 
AC 120V 
AC 230V 
 
 Input 
current 
typ. 
2.34A 
2.05A 
1.23A 
at 24V, 5A see 
Fig. 5-3
 
 Power 
factor 
*) 
typ. 
0.58 
0.56 
0.47 
at 24V, 5A see 
Fig. 5-1
 
  Crest factor **) 
typ. 
2,9 3,1 3,7 
at 
24V, 
5A 
 Start-up 
delay 
typ. 
740ms 900ms 720ms 
see 
Fig. 5-2
 
 Rise 
time 
typ. 
8ms 
8ms 
8ms 
0mF, 24V, 5A, see 
Fig. 5-2
 
   
typ. 
25ms 
25ms 
25ms 
5mF, 24V, 5A, see 
Fig. 5-2
 
 Turn-on 
overshoot 
max. 
400mV 400mV 400mV 
see 
Fig. 5-2
 
 Turn-on 
voltage 
typ. 
75Vac 
75Vac 
N / A 
steady-state value, see 
Fig. 5-1
 
 Shut-down 
voltage 
typ. 
55Vac 
55Vac 
N / A 
steady-state value, see 
Fig. 5-1
 
*) 
The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. 
**)  The crest factor is the mathematical ratio of the peak value to the RMS value of the input current waveform 
 
 
Fig. 5-1   Input voltage range 
 
Fig. 5-2   Turn-on behavior, definitions 
 
Tur
n
-on
90V
Rated input ranges
V
IN
P
OUT
264Vac
180V
S
hut
-down
132V
no
harm
from
132 to
180V
Range
100-
120V
Range
200-
240V
 
 
Start-up
delay
Rise
Time
Ov
ershoot
- 5%
Output
Voltage
Intput
Voltage
 
 
Fig. 5-3   Input current vs. output load 
 
Fig. 5-4   Power Factor vs. output load 
 
6A
1 1.5 2
3
4
0
0.5
1
1.5
2
2.5
3A
Input
Current, typ.
5
Output Current
2.5
3.5
4.5
5.5
230Va
c
120
Vac
100
Vac
 
 
6A
1 1.5 2
3
4
0.35
0.4
5
Output Current
2.5
3.5
4.5
5.5
0.45
0.5
0.55
0.6
0.65
Power Factor, typ.
230Vac
120Vac
100Va
c