Optical Cable Corporation BX002DWLS9KR Fiber Optic Cable Guia De Especificação

Página de 3
Optical Cable Corporation reserves the right to change this specification without prior notification.
inDoor/outDoor cables  |  
i/o 13
breaKout series Fiber optic cable
type oFnr riser proDuct speciFications
Applications
•  Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical
 and environmental protection are necessary
•   Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and
equipment is desired
Features
•  High performance components and construction
•   UL Listed in accordance with NEC sections 770.179(b) for use in vertical  
runs in building riser shafts or from floor to floor
•  Most rugged and easy to install cable design for enterprise cabling applications
•   Core-Locked
outer jacket design for installation  
survivability, long-term, trouble free service
•  Ideal for use in long, vertical installations
•  2.5mm subcables can be direct-terminated with standard
 connectors (2.0mm and 2.9mm subcables also available)
•  Subcabled fiber is environmentally and mechanically protected
•  Ideal for use in point-to-point runs in adverse environments
•   Direct termination to subcable provides additional strain relief for better  
connector retention during moves, adds, and changes
•  Design is ideal for direct pulling with mesh grips
•  Cable materials are indoor/outdoor – UV, water and fungus resistant
•  Wide operating temperature range of -40°C to +85°C
•   High performance 900 µm tight-buffered coating on each optical fiber  
for environmental and mechanical protection
•   Interlocking armor can be applied to cables as an alternative to
 conduit installation
•  2 to 72 fibers
Cost Savings
•   Direct termination to subcable may eliminate the need for patch panels and patch  
cords and reduce connector loss
•   900 µm buffer eliminates the need for costly and time-consuming installation of fanout
 kits or pigtail splices because connectors terminate directly to the fiber. See page PI-6 for
 typical termination approach.
•  High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
B-Series Riser
indoor/outdoor
Operating Temperature
-40°C to +85°C
Storage Temperature
-55°C to +85°C
Installation Temperature (cable temp.)
-10°C to +60°C
Flame Retardancy
UL Listed Type OFNR (UL 1666)
and FT4 (CSA C22.2 No. 232)
Impact Resistance:
1,500 impacts
Crush Resistance:
2,200 N/cm
Flex Resistance:
2,000 Cycles