Sony E 10-18 mm f/ 4 OSS Lens Manual

Página de 111
HELP
SAL55200 (DT 4-5.6/55-200) (DT 55-200mm F4-5.6)
1.
Fold the main PCB assy at the locations shown in the figure.
2.
Install the main PCB assy to main assy, tighten the two screws.
3.
Connect the flexible cable of F.ECD board and Z.ECD board to connector.
Note:
Be carefull about the flexible board not to bend too much.
Be carefull about the flexible board not to come out of the main board.
Main Assy
Outside
F. ECD Board
F. ECD Board
Fold upward
Fold downward
Z. ECD Board
Z. ECD Board
Make sure the Flexible board
does not protrude out of
the main PCB assy.
Inside
Main PCB Assy
Screw