Tamron AF 28-300 mm f/ 3.5-6.3 XR Di LD Aspherical (IF) Macro A06 Lens Manual De Instruções

Página de 97
4-30
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4-9.
ZOOM BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
4-9-1. Zoom Brush Position Adjustment (Search Zoom Adjustment Point)
Equipment
• Personal Computer (PC)
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Remove the zoom rubber ring.
Fig.4-9-1
2)
Peel off the polyester tape (black) 10 mm and remove the zoom ring reinforcement plate and brush cover.
Fig.4-9-2
3)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
4)
Start up of “ActuatorChecker.exe”.
5)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
Zoom Rubber Ring
Brush Cover
Polyester Tape (Black) 10mm
(8x25 mm)
Polyester Tape (Black) 10mm
(8x25 mm)
Zoom Ring Reinforcement Plate
Zoom Ring