Sony AF DT 55-200 mm f/ 4-5.6 SAM Lens Manual

Página de 111
4-33
SAL55200 (DT 4-5.6/55-200) (DT 55-200mm F4-5.6)
Semi Barrel Assy
Main PCB Assy
G11-13 Barrel Assy
Focus Brush
4-8.
FOCUS BRUSH POSITION CHECK/ADJUSTMENT
Equipment
• Adhesive bond (B-10)
1. Preparation
1)
Set the lens to be checked to the condition as shown in Fig.4-8-1 by disassembling or assembling.
Fig.4-8-1
2)
Connect the F.ECD board to the main PCB assy as shown in figure.
3)
Rotate the G11-13 barrel assy, set the infinity position. (Position in which the screw of focus brush is seen.)
Fig.4-8-2