Jablotron Ltd JA80F Manual Do Utilizador

Página de 1
The JA-80F wireless keypad
  
 
 
MHE51301
 
 
The JA-80F wireless keypad 
 
The  JA-80F  is  a  component  of  Jablotron’s  Oasis  80  alarm  system  and  is 
designed to control and program the system. It has a built-in proximity access 
card reader and allows the wiring up of a separate door detector. The battery-
powered keypad communicates wirelessly using Oasis protocol. 
 
Installation 
 
Installation shall only be undertaken by technicians holding a certificate 
issued  by  an  authorized  distributor.  The  keypad  is  for  indoor  installation 
only, typically by the main entrance door. Avoid locating it close to metal 
objects which could shield radio communication. 
1. 
Open the keypad housing (by pressing the tab on the bottom) and 
disconnect the inter-housing connection cable inside (by pulling the 
connector from the board) 
2. 
Install the rear housing to the desired location 
3. 
Install the external hard-wired detector (if required) and route its 
cable through the rear housing  
4. 
Enroll  the  keypad  to  the  control  panel  (see  the  control  panel 
installation manual) as follows: 
  Enter  enrollment  mode  in  the  control  panel  (if  the  system  does 
not  have  a  keypad  already,  briefly  short  the  reset  link  on  the 
control  panel  main  board,  or  if  a  keypad  is  present,  then  press 
key 1 in service mode).  
  Install the battery into the keypad to trigger enrollment.  
  Exit enrollment mode by pressing the # key. 
5. 
Connect  the  inter-housing  cable  to  the  board.  If  a  door  detector 
and an external AC adaptor are used, then connect their cables too.  
Attach the keypad to the rear housing. 
6. 
Instructions  on  how  to  use  the  keypad  can  be  found  in  the  control 
panel operating manual. 
 
Installing a door detector 
 
It is possible to wire up  a detector(s) to the keypad. The IN input terminal is 
triggered when disconnected from GND. The control panel’s natural reaction 
to  the  IN  input  being  triggered  is  a  delayed  intruder  alarm  linked  to  the 
keypad‘s  address.  If  desired,  another  reaction  can  be  programmed  in  the 
control  panel.  The  IN  input  can  indicate  a  door  being  permanently  open 
(status reaction). If the IN input is never used then it must be shorted to GND. 
 
Note:  The  lifetime  of 
the  battery  is  reduced 
proportionally to how 
frequently 
the 
door 
detector 
is 
triggered 
and  how  often  and  how 
long 
the 
keypad 
is 
battery-powered. 
 
Keypad sleep mode 
When battery-powered, the 
keypad  saves  energy  by 
turning itself off when the cover is closed or automatically after 20 seconds of 
inactivity (15 minutes in service mode). The keypad is woken up by: opening 
the keypad‘s flip cover, pressing any key, or triggering the wired door detector. 
Recommendation: install the keypad with the door detector wired to its 
IN terminal. The door detector will always turn the keypad on when the door 
is opened and the keypad can also indicate the entrance delay and be ready 
to read access cards. You will also save money on a wireless door detector. 
Note: If the keypad unit is powered by an AC adaptor there is no sleep mode, 
but 3 minutes after setting the system, status indication stops.  If desired, the 
system setting/unsetting status can be programmed in the control panel to be 
permanently indicate by the keypad.
 
Optional AC adapter 
If the keypad is powered by an AC adapter (model: Jablotron DE01-12 for 
terminals: +U and GND), it will not turn off after 20 seconds of inactivity. If 
the adapter is used, batteries should still be installed. Only turn on the AC 
adapter after the keypad unit has been powered up by batteries and the 
two halves of the housing are back together.
 
 
 
Keypad menu – language selection and door bell function 
If  the 
∗ 
  key  is  kept  pressed  during  battery  connection  the  internal  keypad 
menu will be displayed allowing the selection of the desired language. Using 
the arrows choose your language and confirm selection by the 
∗ 
 key. 
In  this  menu  the  door  bell  function  can  also  be  enabled  or  disabled  (if 
enabled the keypad makes a sound when its IN input is triggered). 
Notes: 
 The menu can be displayed even if the keypad has not been enrolled to 
the control panel.  
 If  you  wish  to  display  the  menu  on  a  keypad  which  already  has  its 
battery installed, disconnect and reconnect the batteries first. 
 Each  keypad  has  its  own  menu,  i.e.  each  keypad  in  the  system  can 
have its own unique settings. 
 The keypad keeps its settings even if its power is disconnected (settings 
can only be altered via the keypad menu).  
 
Testing keypad communication  
In service mode, the control panel allows the keypad’s radio signal to be 
checked,  including  signal  strength  measurement.  To  test  the  keypad 
signal, trigger either its IN input or its tamper sensor. 
Note:  the  control  panel  measures  the  strength  of  the  signal  transmitted 
by the keypad. It is impossible to measure the signal strength received by 
the keypad from the control panel. If the keypad has lost communication 
with  the  control  panel  (e.g.  if  the  control  panel  is  damaged)  it  would 
display  a  communication  error.  If  you  re-power  a  control  panel  which 
previously worked with a keypad, and the keypad does not function, then 
we recommend disconnecting and re-connecting the keypad batteries. 
 
Disabling the tamper sensor 
To  disable  the  tamper  sensor,  short  out  the  jumper  in  the  keypad  unit 
close to the tamper sensor (equipped with a spring). This is useful when 
carrying  the  keypad  unit  around  while  servicing  the  system.  During 
normal use of the system this jumper must remain open circuited.
 
Keypad text editing  
There  are  two  kinds  of  text:  device  and  code  names  (displayed  on  the 
second line after the address number) and other system text. 
  The names can be edited via the keypad after pressing and holding the 
?  key  in  service  mode  –  see  the  control  panel  installation  manual.  The 
edited text is only stored in the keypad unit used for editing. 
  The  most  convenient  way  to  edit  text  is  to  use  a  PC  running  Comlink 
software  (via  the  Devices  window).  To  transfer  edited  text  from  a  PC  to 
the  keypad, the keypad  (with  its batteries  installed)  has  to  be  connected 
to  the  Oasis  system‘s  digital  bus  (i.e.  one  cable  from  the  keypad  to  the  
control panel, and another cable from the control panel to the PC). If there 
are  multiple  keypads,  they  can  all  be  connected  together  (via  the  digital 
bus) while transferring edited text from the PC, or you can transfer text to 
each  keypad,  one  at  a  time.  We  recommend  using  a  digital  bus  splitter 
(model  BS-84).  Comlink  software  also  allows  editing  of  the  keypad’s 
system text (see the menus: Setting/Keypad Text). 
 
Battery replacement 
The  system  checks  the  battery  status  and  if  discharged  it  will  inform the 
end  user  or  the  installer.  The  keypad  will  continue  to  work  but  will  also 
indicate  a low  battery.  Batteries  should  be  replaced  within  2  weeks  by  a 
qualified technician in service mode. 
Do not put expired batteries in the garbage, but follow local regulations.. 
 
 
Removing the keypad from the system 
If the keypad is removed from the system, the control panel indicates this 
event.  If  you  want  to  uninstall  the  keypad,  it  must  also  be  erased  in  the 
control panel. 
 
 
 
Technical specifications 
 
Power supply 
2x lithium batteries type CR14505 (AA 3.0V) 
Typical battery lifetime 
approx. 3 years (with a max.of 2 daily activations) 
Communication frequency 
868 MHz, Oasis protocol 
Communication range 
approx. 100m (open area) 
RFID cards 
Jablotron PC-01 or PC-02 (EM UNIQUE 125kHz) 
Door detector input  
IN = normally closed loop 
Dimensions  
113 x 121 x 63 mm 
Environment according to EN 50131-1  
II. internal 
Operating temperature range 
-10 to +40 °C 
EN 50131-1, CLC/TS 50131-3, EN 50131-5-3 classification 
 class 2 
Can be operated according to 
ERC REC 70-03  
 
FCC ID: VL6JA80F  
 
Jablotron  Ltd.  hereby  declares  that  the  JA-80F  is  in  compliance  with  the 
essential requirements and other relevant provisions of Directive 1999/5/EC and 
complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions:  1.  This  device  may  not  cause  harmful  interference,  and  2.  This  device  must 
accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation.
 
CAUTION:  Changes  or  modifications  no  expressly  approved  by  Jablotron  could  void  the 
user´s  authority  to  operate  the  equipment.
 
The  original  of  the  conformity  assessment  can 
be found at 
www.jablotron.com
, Technical Support section.
 
 
 Note: Although this product does not 
contain  any  harmful  materials  we 
suggest you return the product to the 
dealer or directly to the producer after 
use. 
 
I n t
e r n e t :
  w w w
. j a b l o
t r o n . c
z
T e
l . :   + 4 2
0   4 8 3
  5 5 9  
9 9 9    
f a x
:   + 4 2
0   4 8 3
  5 5 9   9
9 3
4 6
6   0 1   J
a b l o n
e c   n a
d   N i s
o u
z
e c h   R
e p u b
l i c  
OASIS 80
A     
B     
C
ABC
?
B
A
IN
GND
+U