scemtec Transponder Technology GmbH SIR-2720 Manual Do Utilizador

Página de 15
 
 
 Manual and Specification  
SIR-2720 (13.56 MHz Midrange Reader)  
Document No. SIR-2720 
Version:
 
0.04
 
Page  
6 of 14
 
 
 
4.2 
Reading / Writing Tags 
Several  tags  in  the  field  can  be  read  or  written  simultaneously  (
anti-collision).  The  duration  of  the 
reading/writing process depends on the number of tags in the field. Generally, there is no max. number 
of tags that are permitted in the field at the same time. 
 
4.3 
EAS Antitheft 
EAS is an abbreviation of Electronic Article Surveillance. This operating mode serves to monitor items or 
articles  electronically.  The  tags  in  the  field  are  neither  read  nor  written.  The  only  thing  determined  is 
whether  a  tag  is  in  the  field  with  a  set  EAS  mode  flag.  This  mode  allows  for  greater  ranges  than  the 
read/write mode. When using an external antenna such as the scemtec SAT-A40-LR-O-13MHz with an 
edge  length of 400 mm (available as optional equipment), the detection range can be expanded up to 
max. 700 mm.  
 
Note: EAS mode is not supported by all silicon and transponder manufacturers. 
 
 
Hardware 
5.1 
Voltage Supply  
 
The  standard  version  of  the  SIR-2720  reader  in  standard  housing  is  designded  for  an  input  voltage 
range  of  12  Volt  /  =DC  and  a  tolerance  of    +/_  1Volt  .  The  following  input  voltage  ranges  are  thus 
possible with the rated current consumptions in different operating modes: 
 
 
 Input voltage ranges: 
 = DC /  direct current 
12 volt 
 Input voltage - tolerance 
+/_ 1 volt 
 Current consumption of the different operating modes:   
in STANDBY mode:           @12 V / DC power supply 
≤ 150 mA 
while operating(carrier on):@12 V / DC power supply                                    
≤ 800 mA 
 
 
 
For  the  SIR-2720  reader  system  is  a  suitable  wall  plug  12  volt  =DC  /  1000mA  power  supply  also  as 
optional accessory available and contactable to the SIR-2720 over a 2.1-mm standard barrel connector. 
 
5.2 
Safeguarding, fuse-requirements 
Regarding the safety requirements for the SIR-2720 a standard TR5-fuse T1A / 250V (slow blow fuse) is 
used to protect the complete electronics inside against short circuits or overcurrent .  
It is required that this fuse should only be changed by trained technician or skilled personnel ! 
 
 
5.3 
HF Unit 
The carrier frequency of 13.56 MHz is generated in the HF unit. The final stage generates an output of 
max. 1.4 watt on nominal Z
F
 = 50 Ω.