GIGA-TMS INC. MP300 Manual Do Utilizador

Página de 2
MP3xx Wires Assignment
To configure the MP3xx reader you must connect the MP3xx to the PC by RS232C interface using our software.
CAUTION:
The crossed out wheeled bin label that can be found on your product indicates that this
product should not be disposed of via the normal household waste stream.
To prevent possible harm to the environment or human health please separate this
product from other waste streams to en-sure that it can be recycled in an
environmentally sound manner.
For more details on available collection facilities please contact your local government
office or the retailer where you purchased this product.
This information only applies to customers in the European Union.
For other countries, please contact your local government to investigate the possibility
of recycling your product.
TM951339A
Color
Symbol
I/O
Description
Red
VCC
IN
Power Input: Typical with a 12V supply A linear regulator is recommended .
Black
GND
IN
Power Ground + Singal Ground
Yellow
D1
OUT
Clock (ABA TK2) ; Data 1 (Wiegand)
Blue
D0
OUT
Data  (ABA TK2) ; Data 0 (Wiegand)
Green
CP
OUT
Card Present (ABA TK2) 
White
RX
IN
RS232 RXD (To Host TXD)
Orange
TX
OUT
RS232 TXD (To Host RXD)
Brown
Boot
IN
Reboot (While this line wired with GND at power on,MP3xx will enter boot phase.)
MF700KIT is a kit for MP3xx to connect with PC. It is an optional accessory for purchasing.
Remark:
VDC
Orange
White
Green
Red
Yellow
Black
Blue
Brown
To PC RS232C