24 
impulses are terminated on the IDU case by the winding shield, and further – on 
the IDU grounding. 
  
 
The end of the STP service cable that is connected to IDU should be 
assembled with a Shielded RJ-45 connector. The other end of the STP 
service  cable  (connected  to  ODU)  should  be  assembled  with 
unshielded (standard) RJ-45 connector. 
 
IDU  is  grounded  via  a  three-conductor  power  cord  and  a  plug  containing  a 
ground.  The  data  &  power  wires  pickups  are  terminated  via  IDU  protection 
scheme (three-conductor power cord and a plug containing a ground). 
ODU grounding contour are connected with 100kOhm resistor, and that provides 
no static charge accumulation on the ODU case if there are some problems with 
its connection to the grounding contour. 
 
 
Antenna pole, tower, ODU and lightning arrestor should be connected 
to the first common grounding contour. Cable thickness should be no 
less  than  10AWG  using  corrosion-steady  connectors.  IDU  should  be 
grounded  to  the  same  contour  as  customer  LAN,  having  the  second 
common grounding contour. 
 
A special attention should be paid if antenna used is not DC-shorted. In this case 
additional  lightning  arrestor  should  be  used  between  the  antenna  and  ODU. 
Suggested grounding diagram is shown on the picture below.