Infinet Malta Limited LM-5X18 Manual Do Utilizador

Página de 88
InfiNet Wireless R5000 
 
Technical User Manual 
 
Copyright © 2004-2010 by InfiNet Wireless 
79 
 
Enable  Grid  –  draws  grid  lines  and  highlights  the  special  frequency 
channel  on  the  scan  output.  Special  highlighted  frequency  channel  can 
be used to mark a channel that the device is currently working on or that 
is planned for using 
 
Grid  Width  –bandwidth  value  for  the  highlighted  frequency  channel  in 
MHz 
 
Grid  Frequency  –  central  operating  frequency  for  the  highlighted 
frequency channel 
 
Gradient Max RSSI – shows gradient-color marked ―Max RSSI‖ values on 
the Spectrum Analyzer output screen. 
To start/stop «Spectrum Analyzer» use «Start Sensor Test»/«Stop Sensor Test» 
buttons. 
―Last Snapshot‖ button outputs the final scanning results. It is used when doing 
a  spectrum  scan  at  the  remote  unit  on  the  other  side  of  the  radio  link.  When 
running  a  spectrum  scan  at  such  a  unit  (accessible  via  the  RF  interface), 
connection to this unit will be lost for a scan time. "Last Snapshot" button allows 
viewing scan results after the connection is up again. 
 
You  can  get  detailed  information  about  scanned  radio  signals  on  a  specific 
frequency. Just point a cursor on the needed frequency and you will see a hint 
with exact Signal level (dBm), Frequency (MHz), Noise Floor (dBm), RSSI (dBm), 
High RSSI (dBm), Max RSSI (dBm) values.