Lock Testing
Correct lock installation is indicated by three green LED flashes and 
beeps at the end of power on boot up. 
Power On Self Test
The Power On Self Test (POST) is a self-diagnostic that the lock 
runs to verify that the lock is installed correctly. If the red LED lights 
on power up, use the mobile app to see the exact cause of failure.
Capture Lock With Application
Make sure the app is downloaded and ready. The lock must be fully 
assembled, including having the batteries installed. 
Battery cover 
must be installed!
1.  Download the mobile application.
Search for “Schlage Engage” in the App Store.
2.  Set up the mobile application.
Register a new account if you do not have one already.
3.  Select “Connect To Locks” icon at bottom of screen.
4.  Go to “Update Locks,” then “Pending.”
5.  Turn the inside lever and release.
This will put the lock into discoverable mode for 2 minutes.
6.  Pull down on the list on your device to refresh the list of locks.
The lock will show up as “Schlage Lock”
6a.   Select this lock.
6b.   Select “Create new lock”.
6c.   Select “Create from scratch”.
6d.   Enter lock name.
6e.   Press “Save”.
Lock will reset and beep when complete.
Door Position Sensor Calibration
CAUTION
You must calibrate door position! Once lock is  
captured in Engage application, follow instructions  
to calibrate door position!
Construction Access Mode
Construction Access Mode is NOT required to operate lock. 
Construction Access Mode is used to allow access before the lock is 
linked and/or for testing purposes before linking.
Construction Access Mode requires a credential other than a PIN.
•  Enabled by default and after a factory reset.
•  The lock will remain in Construction Access Mode until the 
mode is cancelled as described below.
•  No audits are captured while the lock is in Construction Access 
Mode.
 
L
Once enabled, Construction Access Mode requires a factory 
default reset to exit this mode and allow capture with the 
application.
Create the Master Programming Credential.
The first card presented to a new lock while turning the inside lever 
automatically becomes the Master Programming Credential. The 
Master Programming Credential will not grant access. It is used only 
to add additional credentials.
 
L
Use the same Master Programming Credential for all the 
locks in the facility.
1a  Turn and hold down the inside lever and present to 
the NDE reader the card you want to make the Master 
Programming Credential.
The NDE LED will blink five times for successful enrollment of 
Master Programming Credential.
CAUTION
Do NOT lose the Master Programming Credential. 
If lost, reset the lock to factory settings.
WARNING
If the first card presented to a new lock to create the Master 
Programming Credential is not accepted, the lock has either been 
programmed or already has a Master Programming Credential. If 
the Master Programming Credential cannot be located, or to put the 
lock back into construction access mode, reset the lock to factory 
settings. See Reset to Factory Default for more information. 
Enroll user construction credentials.
2a  Present the Master Programming Credential.
The NDE LED will shine steady green for twenty seconds. You must 
complete the enrollment within this time.
2b  Present credential to enroll for access.
The LED will blink green five times and beep five times if successful.
2c  To enroll more credentials, repeat steps 2a and 2b.
User Guide