6.5.3  Altitude: Operating and Non–Operating 
Operating: to 10,000 ft.(3,040m), (derated 1°C per 1,000 ft. above 5,000 
ft. altitude). 
Non–Operating: 40,000 ft (12,190 m). 
  
6.6  Pollution Degree (WF1101/WF1101) 
Meets requirements for Pollution Degree 2 as defined in IEC 61010-1. 
 
 
 
 
6.7  Dynamics (WF1101/EF1101) 
6.7.1  Random Vibration: Operating and Non–Operating 
 Non–Operating and Operating: 2.28 grms total from 5 to 500 Hz, 20 
minutes each axis, 3-axes, 30 minutes total. 
Profile: 0.0175 g2/Hz 5-100Hz, -3db/octave slope 100-200Hz, 0.00875 
g2/Hz 200-350Hz, -3db/octave slope 350-500Hz, 0.006132 g2/Hz.  Profile 
conducted half in operating and half in non-operating mode 
6.7.2  Functional Shock: Operating 
Three pulses per direction of ½ sine shock @ 30g, 11ms duration.  Total 
of 18 pulses. 
6.8  Transportation And Storage (WF1101/WF1101) 
6.8.1  Transportation Package Material 
Transportation Package material meets recycling guidelines. 
6.9  Electromagnetic Compatibility (EMC) (WF1101/WF1101) 
6.9.1  Emissions 
Emissions shall be within the limits specified by the following 
requirements. 
 
Enclosure: 
 
EN 55011 Class A limits for radiated emissions.