VeriWave Inc. A001Y10 Manual Do Utilizador
VeriWave, Inc. WaveDeploy WiFi(WF1101)/Ethernet(EF1101) Users Guide
Page 23 of 26
6.5.3 Altitude: Operating and Non–Operating
Operating: to 10,000 ft.(3,040m), (derated 1°C per 1,000 ft. above 5,000
ft. altitude).
ft. altitude).
Non–Operating: 40,000 ft (12,190 m).
6.6 Pollution Degree (WF1101/WF1101)
Meets requirements for Pollution Degree 2 as defined in IEC 61010-1.
6.7 Dynamics (WF1101/EF1101)
6.7.1 Random Vibration: Operating and Non–Operating
Non–Operating and Operating: 2.28 grms total from 5 to 500 Hz, 20
minutes each axis, 3-axes, 30 minutes total.
Profile: 0.0175 g2/Hz 5-100Hz, -3db/octave slope 100-200Hz, 0.00875
g2/Hz 200-350Hz, -3db/octave slope 350-500Hz, 0.006132 g2/Hz. Profile
conducted half in operating and half in non-operating mode
minutes each axis, 3-axes, 30 minutes total.
Profile: 0.0175 g2/Hz 5-100Hz, -3db/octave slope 100-200Hz, 0.00875
g2/Hz 200-350Hz, -3db/octave slope 350-500Hz, 0.006132 g2/Hz. Profile
conducted half in operating and half in non-operating mode
6.7.2 Functional Shock: Operating
Three pulses per direction of ½ sine shock @ 30g, 11ms duration. Total
of 18 pulses.
of 18 pulses.
6.8 Transportation And Storage (WF1101/WF1101)
6.8.1 Transportation Package Material
Transportation Package material meets recycling guidelines.
6.9 Electromagnetic Compatibility (EMC) (WF1101/WF1101)
6.9.1 Emissions
Emissions shall be within the limits specified by the following
requirements.
requirements.
Enclosure:
EN 55011 Class A limits for radiated emissions.