Essence Security International ltd. ES700VPD Manual Do Utilizador

Página de 1
 
 
 
 
COMMUNICATIONS 
 
Maximum RF range: Up to 700 m (2296 ft.) – open air 
 
Protocols: Proprietary bi-directional radio protocol 
 
Modulation and frequency: FSK modulation: 
 
868.3 MHz, 869.225 MHz (in Europe and China) 
 
916.5 MHz (in North America) 
 
800 MHz (in Israel) 
 
Data security: 32-bit ID, over 4 billion combinations 
POWER SUPPLY 
 
Battery: Two C-size 1.5V alkaline batteries 
 
Battery life : 3 - 5 years 
 
Input (optional): 90-240 V
AC
, 50/60 H
Z
 external AC adapter 
DIMENSIONS 
 
Size: H – 42 mm (1.65 in.), L – 95 mm (3.74 in.), W – 95 mm (3.74 in.) 
 
Weight: 300 g (0.67 lbs.) not including batteries and accessories  
ENVIRONMENT 
 
Operating ambient temperature range: 0ºC – +45ºC (+32ºF – +113ºF) 
 
Storage ambient temperature: -10ºC – +60ºC (14ºF – +140ºF) 
 
Operating humidity: Up to 100%  
 
Water and dust resistant – IP54 compliant 
COMPLIANCE - Pending 
 
FCC, UL, IC CE, EN50134, AS4607, SRRC 
For more information, go to http://www.essence-grp.com/smart-care 
 
Specifications 
Essence Care@Home™ multi service platform is an Aging-in-Place product 
suite that offers a seamless health monitoring experience allowing 
independence for seniors and peace of mind to their loved ones. 
Care@Home™ allows service providers the flexibility to offer their 
customers services ranging from emergency alerting to a professional 
intelligent home care solution, which constantly learns and adapts to the 
daily behavior of individuals and provides alerts with different severity levels 
based on deviation from the daily routine.  
The Care@Home multi service platform includes: 
 
Care@Home PERS Advanced Emergency Response Alarm 
 
Care@Home Family Monitoring 
 
Care@Home Pro Intelligent Home Care Solution 
ESUGSC017 Rev. 1.1 
Product 
A wireless, smart emergency response device with Intelligent Voice 
Activation™ technology, integrated into the Care@Home™ product suite 
solution, providing an added layer of care by allowing residents to “call for 
help” when unable to press their panic button. 
The Voice Panic Detector features: 
 
Intelligent Voice Activation™ (IVA): an always-active technology that 
recognizes preset vocal commands which trigger specified actions 
 
Stationary panic button and optional pull cord (detachable or fixed) 
 
Two power options: battery operated or external power supply with 
battery as backup 
 
Extreme temperature detection 
 
Voice extender ready (intercom) 
 
LED indications for emergency and system status 
 
Water resistant for installation in shower or bathing areas 
 
Supports automatic over-the-air software (RSU) programming and 
configuration upgrade 
 
Installation using a desktop mount or wall mount using mounting tape 
or screws  
 
Accessories 
 
External pull cord trigger 
 
Desktop mount 
 
AC power adapter  
Smart Care 
 
Care@Home
 
Voice Panic Detector 
ES700VPD 
Smart Emergency Response Device 
© 2016 Essence SmartCare Ltd. Information contained within this document may change without notice 
 
NOTE:    This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
 
- Reorient or relocate the receiving antenna.
 
- Increase the separation between the equipment and receiver.
 
- Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.
 
- Consult the dealer or an experienced radio/TV technician for help.
 
Changes or modifications to this equipment not expressly approved by the party responsible 
for compliance (Essence Ltd.) could void the user’s authority to operate the equipment.
 
This device complies with FCC Rules Part 15 and with Industry Canada license-exempt RSS 
standard(s). Operation is subject to the following two conditions:
 
(1) This device may not cause harmful interference, and
 
(2) This device must accept any interference received, including interference that may 
cause undesired operation 
 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
 
(1) l'appareil ne doit pas produire de brouillage, et
 
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le 
brouillage est susceptible d'en compromettre le fonctionnement.