Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0 
Confidential and Proprietary 
 
 
December 12, 
2011 
 
 
 
The Strata label defines the model and serial number of the Underground Silent Zone 
Generator also MSHA and Commonwealth of Pennsylvania information. 
1.3.1.1 
MSHA Blasting Distance 
MSHA has published Program Policy Letter P11-V-07 concening Two Way Communications and 
Blasting Circuits. 
 
SPS magnetic field generators produce a magnetic field that at 100 kHz or .1000 MHz does not 
achieve the Critical H Field until 1.42 m with a blasting cap having a pickup area of 10 sq. 
meters.   
 
SPS magnetic field generators are safe to 1.42 m from the blasting caps.  SPS does recommend 
a minimum distance of 25’ as a precaution. 
1.3.1.2 
Pennsylvania Blasting Distance 
At this date, Pennsylvania has not made a recommendation or statement concerning surface 
systems.  
1.4  FCC Information 
The FCC ID for the Underground Silent Zone Generator is ZQ3-SPS-USZON.  When configured by 
Strata for underground use, the device complies with Part 15 of the FCC Rules.  Operation is 
subject to the following conditions: 
 
(1) This device may not cause harmful interference. 
(2) This device must accept any interference received including interference that may 
cause undesired operation. 
 
Any intentional or unintentional changes or modifications to the configuration of the 
Underground Silent Zone Generator not specifically detailed in this document could void the 
user’s authority to operate the equipment.