WABCO GmbH OPTITIRE Manual Do Utilizador

Página de 52
 
 
 
 
OPTITIRE
 
 
Operation 
 
 
 
 
 
 
 
30 
   
 
–  Repeatedly push left button to display the axles of the towing vehicle as well the 
axles of the towing vehicle. 
 
  The display will switch back to normal mode if no button has been pushed for a 
period of 20 seconds. 
5.4 
Display of faults 
When the OPTITIRE detects a fault, an amber or red warning lamp illuminates. 
Proceed as follows to display the type of fault on the vehicle: 
–  Push right button after lighting up of amber or red warning lamp. 
 The pressure value of the affected wheel will be indicated and the position 
on the vehicle is indicated by a flashing wheel icon. 
If no current defect is found the system does not react to pressing right but-
ton. 
The link ed image cannot be display ed.  The file may hav e been mov ed, renamed, or deleted. Verify  that the link  points to the correct file and location.
 
fig. 5-5: 
Display of faults 
 
  If the system warns about several tires then the tire with the most serious fault is 
indicated first. 
Repeated pressing of right button will show further faults. 
The link ed image cannot be display ed.  The file may hav e been mov ed, renamed, or deleted. Verify  that the link  points to the correct file and location.
 
fig. 5-6: 
Creeping pressure loss 
The individual fault types are shown in the following: