Racom RIPEX-154 Manual Do Utilizador

Página de 157
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Fig. 4.6: Supply connector
Wire
Ports (7)
Retaining
Screws (2)
Lead
Binding
Screws (7)
Fig. 4.7: Power and Control - cable plug
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Sleep Input
SLEEP INPUT
SLEEP INPUT is the digital input for activating the Sleep mode.
When this pin is grounded (for example when connected to pin
3), the RipEX switches into the Sleep mode. Using Power man-
agement (Advanced Config.), the Entering the Sleep mode can
be delayed by a set time. Disconnecting SLEEP INPUT from
GND (-) ends the Sleep mode. Note that RipEX takes 25 seconds
to wake up from the Sleep mode.
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Alarm Input
HW ALARM INPUT
HWALARM INPUT is a digital input. If grounded (e.g. by connect-
ing to PIN 3), an external alarm is triggered. This alarm can be
used for example to transmit information using SNMP trap, in-
forming for instance about a power outage or RTU problem. For
details about Alarm management see chapter Advanced Config-
uration
.
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Alarm Output
max. 30 V DC, 1 A
HW ALARM OUTPUT
HW ALARM OUTPUT is a digital output. It can be activated
in Alarm management settings, chapter Advanced Configuration.
It may be used for instance to switch on the Fan kit if the preset
maximum internal temperature is exceeded or to inform the
connected RTU about a RipEX alarm. If an alarm is triggered,
HW ALARM OUTPUT is internally connected to GND. If the ex-
ternal device requires connection to positive terminal of the power
supply, PIN 4 should be used.
POWER
The POWER pins labelled + and - serve to connect a power supply 10–30 VDC. The requirements for
a power supply are defined in Section 6.6, “Power supply” and Section 4.4, “Technical specification”.
41
© RACOM s.r.o. – RipEX Radio modem & Router
Product