Homewerks Worldwide LLC 7130-02-BT Manual Do Utilizador

Página de 4
12
www.homewerksww.com
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan seems louder than 
it should
CFM too great
Be sure the CFM rating on the fan matches the 
size of your room.
Damper not working properly or damaged
Check damper to ensure it is opening and closing 
properly. If the damper has become damaged, 
please call Customer Service.
Bend in duct too close to fan discharge
Be sure you do not have any sharp bends in duct 
closer than 18 in. to the fan discharge.
Fan discharge reduced to fit smaller duct
Use recommended size ducting to reduce fan 
noise.
Fan body not securely attached
Be sure the fan is securely attached to your ceiling 
joists.
The fan is not  
clearing the room
Insufficient intake airflow within room
Be sure a door or window is slightly ajar or opened 
to allow airflow. The fan is not able to draw air out of 
the room without enough airflow to draw from.
Insufficient CFM
Be sure the CFM rating on the fan matches the 
requirements for your room size.
NOTE: Using a tissue is not an accurate method 
for determining if the fan is operating properly. If the 
fan clears steam from the room  
within approximately 15 minutes of completing your 
shower, then the fan is operating properly.
Device will not pair
Another device is already paired.
Make sure BLUETOOTH
®
 signal is turned off on 
other devices.
4.  Replace the BLUETOOTH
®
 speaker and grille. 
 
Turn on power source.
CARE AND MAINTENANCE
4