PTM 210 / 210C STEP EA 
 
Processor 
Converts the contact nipples’ status and pushed/released data from the power generator 
into a reliable and energy-efficient serial telegram structure. 
 
HF transmitter 
Sends the data in the form of a series of short radio signals. 
 
2.2  Contact Nipples Designation 
 
With  4  contact  nipples,  the  PTM  210  offers  2  channels  with  4  action  states  each  (up-
per/lower nipple is pressed/released when activating the energy bow). The nipples’ desig-
nation is as follows: 
 
 
Contact nipple designation 
 
 
Radio signals of the PTM 210 device are event-controlled (energy bow is pressed/released) 
with contact nipple code (channel/state) and unique device identification (fixed 32-bit ID). 
When operating more than one nipple at the same time, note that PTM 210 sends multiple-
button code combinations: 
 
 
N-message: One or two contact nipples have been pressed when activating the energy 
generator  Message with nipple code and pressed/released event status of the energy 
bow is sent. 
 
U-message: No contact nipple was pressed when activating the energy generator, or 3 
or  4  nipples  have  been  pressed    Message  with  pressed/released  event  status  of  the 
energy  bow  is  sent  and  the  information  if  either  none  or  more  than  two  nipples  have 
been pressed. Note that it can’t be differentiated if 3 or if 4 nipples have been pressed.  
 
 
Due to the mechanical hysteresis of the energy bow, in most rocker switch device 
implementations, pressing the rocker sends an N-message and releasing the rock-
er sends a U-message! 
 