Server
ȱandȱSensorȱOverviewȱ
SpectraGuard
®
ȱEnterpriseȱInstallationȱGuideȱ
Table 6.
Rear Panel Port Settings for SS-200-AT 
Port 
Description 
Connector Type 
Speed/Protocol 
Serial 
Enables a serial connection to 
establish terminal sessions; 
used for launching Config Shell 
sessions 
DB-9 
Settings:
Bits per second: 9600 
Data Bits: 8 
Parity: None 
Stop Bits: 1 
Flow Control: None 
Protocol: RS-232 
Ethernet 
Enables the device to be 
connected to the wired LAN 
through a switch or a hub. This 
connection allows the Sensor to 
communicate with the Server 
RJ-45 
Settings:
10/100 Mbps 
Protocol:
Ethernet 
ȱ
Note:ȱTheȱSpeed/ProtocolȱsettingsȱmentionedȱinȱtheȱaboveȱtableȱareȱtheȱsameȱforȱHypeȱTerminalȱandȱminicom.ȱ
3.5
Rear
ȱandȱSideȱPanelsȱofȱSensorȱSSȬ300ȬATȱ
TheȱrearȱpanelȱofȱtheȱSensorȱSSȬ300ȬATȱhasȱanȱEthernetȱportȱthatȱenablesȱtheȱdeviceȱtoȱbeȱconnectedȱtoȱtheȱwiredȱLANȱthroughȱ
aȱswitchȱorȱaȱhubȱandȱalsoȱprovidesȱtheȱpowerȱforȱtheȱdeviceȱusingȱ802.3afȱstandard.ȱȱ
ȱ
Figure  8.
Rear Panel of Sensor SS-300-AT 
TheȱSensorȱhasȱtheȱfollowingȱports:ȱ
x
Ethernet
ȱport:ȱConnectsȱtheȱSensorȱtoȱtheȱnetworkȱandȱalsoȱprovidesȱtheȱpower.ȱ
Table 7.
Rear Panel Port Settings for SS-300-AT 
Port 
Description 
Connector Type 
Speed/Protocol 
Ethernet 
This enables the device to be 
connected to the wired LAN 
through a switch or a hub. This 
connection allows the 
SpectraGuard Sensor to 
communicate with the 
SpectraGuard Enterprise® 
Server.
This port also provides the 
power for the device using 
802.3af standard 
RJ-45 
10/100/1000 Mbps 
Ethernet 
Power over Ethernet 
ȱ