Mojo Networks Inc. SS300AT Manual Do Utilizador

Página de 117
Manually
ȱConfiguringȱtheȱSensorȱ
SpectraGuard
®
ȱEnterpriseȱInstallationȱGuideȱ
34ȱ
x
SNDC
ȱMode:ȱThisȱmodeȱneedsȱtoȱbeȱexplicitlyȱconfigured.ȱInȱthisȱmode,ȱtheȱSensorȱshouldȱbeȱconnectedȱintoȱaȱ
trunk
ȱportȱ(802.1Qȱcapable)ȱonȱaȱswitch.ȱItȱthenȱmonitorsȱmultipleȱVLANsȱthatȱareȱconfiguredȱonȱthatȱtrunkȱportȱandȱ
areȱchosenȱbyȱtheȱuserȱusingȱtheȱNDȱCLI.ȱTheȱwirelessȱinterfaceȱofȱtheȱSensorȱisȱenabled.ȱAȱSensorȱinȱSNDCȱmodeȱ
canȱmonitorȱupȱtoȱ4ȱVLANsȱandȱdetectȱupȱtoȱ4ȱVLANs.ȱ
UseȱtheȱsetȱmodeȱcommandȱtoȱsetȱtheȱSensorȱmode.ȱ
ȱ
Figure  59.
set sensor mode command 
6.2.5 ConfigureȱNetworkȱSettingsȱ
Onceȱtheȱmodeȱisȱset,ȱyouȱhaveȱtoȱenableȱtheȱNetworkȱSettings.ȱ
x
Sensor
ȱOnlyȱMode:ȱForȱthisȱmode,ȱuseȱtheȱcommandȱsetȱipȱconfig.ȱThisȱcommandȱrunsȱthroughȱtheȱcurrentȱVLANȱ
andȱtheȱIPȱconfigȱwizard.ȱ
x
Network
ȱDetector/Sensor/NDȱComboȱMode:ȱForȱthisȱmode,ȱuseȱtheȱcommandȱsetȱvlanȱconfig.ȱThisȱcommandȱ
configuresȱtheȱIPȱaddressesȱonȱtheȱND.ȱ
ReferȱtoȱChapterȱ3:ȱGuidelinesȱforȱConfiguringȱandȱInstallingȱNDȱandȱSNDCȱinȱtheȱdocumentȱ‘NetworkȱDetectorȱ
ConfigurationȱforȱSpectraGuardȱEnterprise_5.7’ȱforȱfurtherȱdetails.