SS‐300‐AT‐C‐60 Installation Guide 
21
Chapter 8 
Appendix A: Server Sensor Mutual Authentication 
The Sensor‐Server communication begins with a mutual authentication step in which the Sensor and Server authenticate each 
other using a shared secret. Sensor‐Server communication takes place only if this authentication succeeds. 
Once authentication succeeds, a session key is generated. All communication between the Sensor and Server from this point 
on is encrypted using the session key.  
The Sensor and Server are shipped with the same default value of the shared secret. The CLI commands are provided on both 
Server and Sensor for changing the shared secret. 
Note: Once the shared secret (communication key) is changed on the Server, all Sensors connected to the Server will automatically be 
setup to use the new communication key. Sensors that are not connected to the Server at this time will need to be setup with the same 
communication key for them to be able to communicate with this Server. 
 
Note: While the Server is backward compatible, that is, pre version 6.7 Update 1 Sensors can connect to a version 6.7 Update 1 Server, this 
is not recommended. Once all Sensors have been upgraded to version 6.7 Update 1, the set sensor legacy authentication
 
CLI command 
can be used to disable older Sensors from connecting to the Server.