Radiolink Electronic Limited RL037T001A Manual Do Utilizador

Página de 31
13
Dual Rates / Exponential Settings  
The aileron, elevator and rudder dual rates on the T7F are simultaneously activated by the dual rate switch. The amount 
of travel decrease for each control may be set between 0% and 100% of the values set for the end points.(explained in 
End Point Adjustment on page 13).  
Note
: It is possible to set a dual rate value to zero, thus causing no response from that channel. If the dual rates are 
inadvertently set to zero, a crash could result.  
Note
: When performing initial model setup, the E.P.A.s should be set prior to setting the dual rates. When setting the E.P.
A.s for the first time on a new model, the dual rates should be set to 100%.  
D/R    Dual Rate Settings  
To set the dual rates:  
1.Enter the programming mode. Access the “D/R” screen with the MODE“▲”or“▼” key.  
2.Select the channel to be adjusted (1-aileron, 2-elevator, 4-rudder) by pressing the SELECT 
key until the desired channel number appears on the left side on the screen. Note: If an 
“EXPO”
 appears on the screen, you have pressed the SELECT key too many times and 
displayed the values for the exponentials (explained later). Press the SELECT key to return 
to the dual rate values.  
3.Place  the  dual  rate  switch  in  the  desired  position  for  the  value  you  wish  to  change. 
(Generally, pilots prefer to have the switch in the “up” position for the high rate, and in the 
“down” position for the low rate.)  
 4.Change the dual rate value using the DATA “+” or “-” key until the desired control throw is achieved. If you wish to 
change the control throw when the switch is in the other position as well, flip the switch, then use the DATA “+” or “-” key 
to change the throw.  
5. Repeat the procedure for the other dual rate (channel 2-elevator, 4-rudder). 
EXPO    Exponential Settings  
The “exponentials” are in the same function as the dual rates. (Pressing the MODE “▼” key will take you to the next 
function which is End Point Adjustments). The same as dual rates, “expos” can be set for both switch positions. Negative 
exponential (-) decreases initial servo movement. Positive exponential (+) increases initial servo movement. The 
exponential “curve” may be set anywhere between -100% and +100%.  
To set the exponentials:  
1.Enter the programming mode. Access the “D/R”
 screen with the MODE“▲”or“▼” key.  
2.Access the “EXPO” screen with the SELECT key.  
3.Select the channel (1-aileron, 2-elevator, 4-rudder) you wish to set by pressing the 
SELECT key. The active channel number will be displayed on the screen. Note: If a “D/R” 
appears on the screen, you have pressed the SELECT key too many times and displayed 
the values for the D/R (dual rate values). Press the SELECT key to return to the 
exponentials. 
4. Position the dual rate switch where desired for the value you wish to change.  
 
5.Enter the amount of exponential with the DATA “+” or “-” key. (As stated above, an exponential value with a “-” in front of 
it makes the initial servo movement less, or “softer. ”)  
6.Flip the switch to the other position to enter the exponential value for that switch position.  
7.Repeat for the settings on the other channel. 
EPA    End Point Adjustment 
Note
: Since changing the “end points” will also change the dual rates, the end points should be set prior to setting the dual 
rates. If you set the dual rates first, and then go back and change the end points, the dual rate throws will also change.