Mitel Deutschland GmbH 68635RFP36U-01 Manual Do Utilizador
SIP-DECT OM System Manual
272
Each of this these access types uses the same account data.
The account data can be altered at the
User account page of the OMM Web.
The OMM delivers all the necessary account data to all connected RFPs. The RFPs save the account
data inside their permanent memory. This has some implications:
data inside their permanent memory. This has some implications:
•
An RFP out of the box uses the default account data as long as this RFP is not connected to the
OMM.
•
An RFP which was connected for at least one time with the OMM uses the account data from the
OMM.
•
When the account data are changed on the OMM, any not connected RFPs will continue to use the
older passwords.
7.17.1 ACCOUNT TYPES
There are three different account types:
•
Full access: This access type is the “normal” access for the configuration. Using this access it is
allowed to configure the OMM and each RFP. On the SSH interface of an RFP this access type
allows login for debug information e. g. “pinging” another RFP to check visibility.
allows login for debug information e. g. “pinging” another RFP to check visibility.
The factory setting for this account is
Name:
Name:
'omm'
Password: 'omm'
Active:
Active:
'n/a'
•
Read-only access: As the name suggests this access type is not allowed to configure any item of the
OMM installation. This access type can only be used on the OM Web service. The account can be
deactivated.
deactivated.
The factory setting for this account is
Name:
Name:
'user'
Password: 'user'
Active:
Active:
'yes
•
Root (SSH only) access: This access type is only applicable on the SSH interface of an RFP. Its
purpose is to get detailed information e. g. parameters from the kernel. The access using this account
type is not reachable from other hosts hence a login using the full access type is necessary.
type is not reachable from other hosts hence a login using the full access type is necessary.
The factory setting for this account is
Name:
Name:
'root'
Password: '22222'
Active:
Active:
'n/a'
Please note:
It is highly recommended not to use the “Root (SSH only) access” account
type. It is meant for technical support only.
7.17.2 POTENTIAL PITFALLS
When an RFP is configured via the OM Configurator and is taken out of an installation, the RFP may
become unusable:
become unusable: