Mitel Deutschland GmbH 68635RFP36U-01 Manual Do Utilizador
SIP-DECT OM System Manual
48
Small systems – 1 .. 5 DECT base stations
•
No license required
•
Telephony and basic messaging only
•
No locating or enhanced messaging functionality
•
PARK code for up to 256 DECT base stations required for operation (provided by the online PARK
service)
Note: Existing SIP-DECT systems with up to five L-RFPs are
automatically migrated to the integrated license model. Larger
systems still require a valid license file.
systems still require a valid license file.
Medium systems – up to 256 DECT base stations (minimum 3 DECT base stations)
•
OM System License required for the number of DECT base stations (10, 20, 50, 100, etc)
•
Licenses for Messaging and Locating can be added
•
PARK code for 256 DECT base stations included in license file
Large systems – up to 4,096 DECT base stations
•
OM System License required for the number of DECT base stations
•
OpenMobility Manager (core software) resides on one or two Linux-based PCs
•
Licenses for Enhanced Messaging and Locating can be added
•
PARK code for 4096 DECT base stations included
Note: With SIP-DECT Release 6.0 or later, there is no longer a
demonstration mode for the OMM.
4.1.2 ABOUT G.729 CHANNELS
With SIP-DECT Release 6.0 or later, the number of G.729 channels is no longer limited to a specific
fixed number or license. The number of G.729 channels depends only on the resources available (i.e.,
DECT base station capacity and number of base stations).
fixed number or license. The number of G.729 channels depends only on the resources available (i.e.,
DECT base station capacity and number of base stations).
4.1.3 PARK SERVICE
A Portable Access Rights Key (PARK) is required to operate a SIP-DECT system with up to five DECT
base stations. (For systems with more than five DECT base stations, the generated license file contains
the PARK code). With SIP-DECT 6.0 or later, the PARK code is provided via a centralized Web service;
you do not need to enter the code manually (as in earlier SIP-DECT releases). A PARK for up to 256
DECT base stations is available upon request from the OMM Web service.
base stations. (For systems with more than five DECT base stations, the generated license file contains
the PARK code). With SIP-DECT 6.0 or later, the PARK code is provided via a centralized Web service;
you do not need to enter the code manually (as in earlier SIP-DECT releases). A PARK for up to 256
DECT base stations is available upon request from the OMM Web service.