Check the signal strength once the control valve and wireless remote are setup.  On the Softener Controller, go to the Main 
Menu/Advanced setup/Diagnostics/Test Wireless to check signal strength.  The signal strength indicator (SSI) will show a 
value of between 0 and 8.  If the SSI is at least 4, then the installation is complete.  It the SSI drops below 4, then it may be 
necessary to select an alternate location for the wireless remote.
From the home screen, press the DOWN arrow to ADV SETUP.  Press the CHECK MARK 
button.
Press the DOWN arrow to scroll to DIAGNOSTICS.
Press the DOWN arrow to scroll to TEST WIRELESS.
From the TEST WIRELESS screen, press the CHECK MARK button to test.
Installing the Modem (optional)
Note: The modem can be installed into either the back of the main controller or the back of the remote control board.  The 
functionality of the modem is the same in either installation with the important exception that automatic firmware updating is 
ONLY available on units which have the modem installed on the main controller.
   Before installing the modem into the back of the GBE board or the back of the remote, the GBE circuit board or the 
remote must first be powered off.
   When handling all circuit boards, take care to only touch the edges of the circuit boards – not the metal pins.   The 
electronics on all circuit boards can be damaged by static electricity.
   Make sure all of the pins at all four connectors are aligned between the modem board and the main controller board.  
Make sure that the modem board is fully seated into all four sockets.
 When all connections have been made restore power.
1.
2.
3.
4.
 > 5) adv setup
system ok
7:32 am 2-1-08
 > 5) diagnostics
 > 3) test wireless
 wireless test
230/230 rssi=8
 
Installation of Accessories 
38
 37
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER