24
4.4.3
Installing the Extended Interface Board
1. Determine the installation location and install using
the six (6) screw locations.
2. Install a ground wire from the EIB panel to the
ground bus bar.
If possible, install the ground lug to the rear of the
EIB panel where the surface is not painted.
Alternately, remove paint from around one hole on
the front of the panel’s mounting flange.
EIB panel where the surface is not painted.
Alternately, remove paint from around one hole on
the front of the panel’s mounting flange.
For best performance, equipment ground wires
should be constructed using UL-listed compression-
type connectors and 14-gauge or larger stranded
ground wire. Always use gradual bends in the wire
(no sharp angles).
should be constructed using UL-listed compression-
type connectors and 14-gauge or larger stranded
ground wire. Always use gradual bends in the wire
(no sharp angles).
4.5 CABLE CONNECTIONS
Figure 4-1 represents a 4-channel rackup. Up to four (4) rackups similar to that shown in Figure 4-1 may
be connected for a maximum of 16 RF channels at one site. Backplane connections at each of the four
rackups are similar with only cable additions for interconnecting the multiple rackups.
be connected for a maximum of 16 RF channels at one site. Backplane connections at each of the four
rackups are similar with only cable additions for interconnecting the multiple rackups.
4.5.1
Initial Backplane Cable Connections
Before installing cables, the equipment shelves and grounding system should be installed as per the
previous sub-sections.
previous sub-sections.
CAUTION
Make sure all AC and DC power input is Off or disabled before making connections to
the equipment.
the equipment.
1. Make the following backplane cable connections as shown on Figure 4-1.
a. Cable from EIB LAN&E1 connection to the transceiver shelf J46, J47, and J52 connections.
b. Cable from EIB’s CAN connection to the transceiver shelf J28.
c. Cable from EIB’s RS485 connection to the fan shelf J29.
d. Cable from transceiver shelf J34 to the fan shelf RS485_M.
e. Cable from transceiver shelf J35 to the fan shelf DC input.
f. Cable from transceiver shelf J36 to the fan shelf DC input.
g. Cable from transceiver shelf J33 to the fan shelf CAN_M.
h. Customer supplied AC power cable Chassis GND wire to transceiver shelf J44-PE.
i. Customer supplied AC power cable Neutral wire to transceiver shelf J44-N.
j. Customer supplied AC power cable Leg 1 (L1) wire to transceiver shelf J44-220V.