Installing the Extended Interface Board 
1.  Determine  the  installation  location  and  install  using 
the six (6) screw locations. 
 
2.  Install  a  ground  wire  from  the  EIB  panel  to  the 
ground bus bar. 
If  possible,  install  the  ground  lug  to  the  rear  of  the 
EIB  panel  where  the  surface  is  not  painted.  
Alternately,  remove  paint  from  around  one  hole  on 
the front of the panel’s mounting flange. 
For  best  performance,  equipment  ground  wires 
should  be  constructed  using  UL-listed  compression-
type  connectors  and  14-gauge  or  larger  stranded 
ground wire.  Always use gradual bends in the wire 
(no sharp angles). 
 
4.5  CABLE CONNECTIONS 
Figure 4-1 represents a 4-channel rackup.  Up to four (4) rackups similar to that shown in Figure 4-1 may 
be connected for a maximum of 16 RF channels at one site.  Backplane connections at each of the four 
rackups are similar with only cable additions for interconnecting the multiple rackups. 
4.5.1 
Initial Backplane Cable Connections 
Before  installing  cables,  the  equipment  shelves  and  grounding  system  should  be  installed  as  per  the 
previous sub-sections. 
 
CAUTION
 
Make sure all AC and DC power input is Off or disabled before making connections to 
the equipment. 
1.  Make the following backplane cable connections as shown on Figure 4-1. 
a.  Cable from EIB LAN&E1 connection to the transceiver shelf J46, J47, and J52 connections. 
b.  Cable from EIB’s CAN connection to the transceiver shelf J28. 
c.  Cable from EIB’s RS485 connection to the fan shelf J29. 
d.  Cable from transceiver shelf J34 to the fan shelf RS485_M. 
e.  Cable from transceiver shelf J35 to the fan shelf DC input. 
f.  Cable from transceiver shelf J36 to the fan shelf DC input. 
g.  Cable from transceiver shelf J33 to the fan shelf CAN_M. 
h.  Customer supplied AC power cable Chassis GND wire to transceiver shelf J44-PE. 
i.  Customer supplied AC power cable Neutral wire to transceiver shelf J44-N. 
j.  Customer supplied AC power cable Leg 1 (L1) wire to transceiver shelf J44-220V.