Aclara Power-Line Systems Inc. Y72553-1 Manual Do Utilizador

Página de 86
T W A C S
®
- O R I O N
®
  f o r   U M T   P r o d u c t s   U s e r   G u i d e
35
Chapter 2 • Functional Description
RCE Change Out
At some point an Electronic Metering Assembly (EMA), Electric Meter 
Transceiver-3 (EMTR-3), or both may need replacement. Assuming that the old 
EMTR-3 is still functional, the original port list can be downloaded to the HHTR-3 
prior to removal of the old Remote Communication Equipments (RCE). After RCE 
replacement, the stored port list can be uploaded to the new EMTR-3 and operation 
may resume. This process can be carried out with the RCE Change Out menu 
selection. This selection allows the user to confirm proper installation and test the 
network. 
Use the following procedures to navigate the RCE Change Out screens.
Extract Port List
1.   
From the EMTR3 Menu, use the Up or Down arrow keys to select RCE 
Change Out.
2.   
Press the 
Enter
 key to enter the serial number of an EMTR whose Port List 
is to be reused (preserved).
3.   
Press 
Enter
 to accept and view the RCE Change Out menu.
4.   
Use the Up or Down keys to select Extract Port List.
EMTR3 Menu
Manage IEDs
EMTR-3 Status
RCE Change Out
Select EMTR
Enter Serial Number
EMTR S/N________
Enter to Accept
RCE Change Out
Install Port List
Select:
Extract Port List
DRAFT